![ATX ChromaFlex Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/atx/chromaflex/chromaflex_operation-manual_3006226080.webp)
SNMP ENTERPRISE ATTRIBUTES
7-12
ChromaFlex Chassis – Operation Manual
ATX Confidential & Proprietary
MAX-ACCESS read-write
STATUS current
DESCRIPTION
“User gain setting in dB.
Note: the write access only apply to modules with changeable gain.”
::= { innoTransCFlexModuleAnalogEntry 27 }
---
--- TRAPS
---
iTCFlexNotifications OBJECT IDENTIFIER ::= { innoTransCFlex 3 }
iTCFlexNotification OBJECT IDENTIFIER ::= { iTCFlexNotifications 0 }
iTCFlexNotificationObjects OBJECT IDENTIFIER ::= { iTCFlexNotifications 1 }
--
-- Notification objects
--
notifyObjectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
“The integer object reports the interface index number from 1 to 4.”
::= { iTCFlexNotificationObjects 1 }
notifyObjectValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
“The value of the notification object.”
::= { iTCFlexNotificationObjects 2 }
HeCommonLogState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
“The new alarm state of the object which caused the event
to be recorded into the log.”
SYNTAX INTEGER {
heCommonNominal(1),
heCommonHIHI(2),
heCommonHI(3),
heCommonLO(4),
heCommonLOLO(5),
heCommonDiscreteMajor(6),
heCommonDiscreteMinor(7)
}
notifyAlarmState OBJECT-TYPE
CHAPTER 7: