background image

 

 

Switch Specifications

 

Power source and Pass Thru 

Spring loaded connectors  ( 2 pairs )  
for AWG 16-20 wire

 

LED constant current output 

660 mA with dimming to 30 mA (B) or 3 mA 
Spring loaded connectors ( 2 pairs )  

FAN output 

12 volts, 1 amp with speed control to 7 volts 

Input voltage range 

24v to 52 volts ( power for LEDs)

 

Standby power consumption  

50 milliwatts 

Conversion efficiency  

Over 95% 

Protection 

Reverse protection and static protection 

Operating Temperature 

0°C ~ 50°C 

 

Size 

108H (metal) 70H   x 34 D x 42 W mm

 

Dimming 

100% to 0.5% ( 5% B) 

FCC and interference 

 All outputs are RF filtered for minimal  
interference, FCC compliance tested 

Maximum output voltage 

 Input minus 4 volts 

Minimum output voltage 

 6 volts, self calibrating 

Strip LED support ( CV Mode) 

Autodetect 24v CV strips  

Protection 

Short Circuit, Overvoltage, hot swap – you can  
unplug and connect LEDs with power applied.  

User Error tolerant 

Detects and displays user errors 

DALI interface 
Individual, group and scene 
support ( Optional) 

Opto Coupled AWG 18-24 gauge wire spring fit 
short and long  addresses 16 to 24 volts 2 mA 

N-Way input 

Simple contact for Fan control 
see “Software N-Way Operations” 

LED output A 

Top Left 

LED / PIR / Fan output B 

Top Right 

FAN Timer 

0 to 90 minutes – using DALI commands 

 

 

 

Exhaust Fan – ATX FAN 12v 

Description

 

Low noise ceiling/wall mount ventilating fan with super low profile, rated for continuous running. It uses the SLM70 assembly 
which is ENERGY STAR® qualified and is HVI, UL, and cUL certified, and can be used to comply with ASHRAE 62.2 (local 
and whole building intermittent operation). The adaptation to 12v is pending UL.

 

DC Motor/Blower

 

 

Working voltage 12Vdc, operating voltage 8~12Vdc

 

 

Insulation strength 10M Ohm(Min.)

 

 

Dielectric strength 700VAc 60Hz

 

 

Start-up inrush current limited to 240 mA non-inductive load, steps up to 1 amp after 300 mS

 

 

Built in soft start function

 

 

Motor equipped with thermal cutoff fuse

 

 

Locked rotor protection, powers OFF when impeller is locked abnormally

 

 

Removable with permanently lubricated plug in motor

 

 

DC brushless motor engineered to run continuously

 

 

Built in polarity and overvoltage protection

 

Housing

 

 

Galvanized steel body

 

 

Detachable 3” diameter duct adapter

 

Содержание AL-FF-100

Страница 1: ...le switch found at Home Depot can be used or the AL WS M momentary switch can be used for advanced timer controls Stand alone it operates as a simple switch for 1 strings of LED s and 1 fan Use AWG 16 or 18 to bring 48v or 24 to 52 volts from a central power supply over to the switch then use AWG 20 to connect to your LED and Fan no crimping tools are required to wire this device A proven rocker s...

Страница 2: ...oupled AWG 18 24 gauge wire spring fit short and long addresses 16 to 24 volts 2 mA N Way input Simple contact for Fan control see Software N Way Operations LED output A Top Left LED PIR Fan output B Top Right FAN Timer 0 to 90 minutes using DALI commands Exhaust Fan ATX FAN 12v Description Low noise ceiling wall mount ventilating fan with super low profile rated for continuous running It uses the...

Страница 3: ...Wiring the AL WS DR2 Fan and Light ...

Страница 4: ...watts of LED loads Series LED wiring The LEDs are wired in series The simple strip and poke OJ 606 connectors are easy to install in ceilings If you only cut the Red wire you can save time and work by wiring as shown at left From 1 to 5 LEDs can be connected on each side Set the jumpers for 300 360 660 or 720 mA Note for 6 watt LEDs a 5 in series at 660 mA 51v b 4 in series at 660 mA 48v c 2 in se...

Страница 5: ...change back to On Off type See below Restore to Momentary Style 5 times second Should the light not stay on when the momentary switch is pressed the device is in Rocker mode for example after factory default Press the button 5 times with less than 0 5 seconds each to change to Momentary operation Main switch functions On Off style A momentary switch springs back to On when the lever is pressed dow...

Страница 6: ... the switch on or off It will turn on immediately and stay on 10 minutes after the light is turned off Turn the fan switch off to return to manual mode B Timer If the fan switch is left on then each time the light is turned on after 90 seconds the fan will turn on and stay on for 10 minutes and turn off automatically For momentary switches A Press to start each press adds 5 minutes run time enable...

Страница 7: ...s after provisioning the mechanical front switch in this device is placed into either short address or Group mode see below flipping the switch or the 3 way remote switches or the slider dimming value will cause a DALI command to be sent internally to the LED outputs as well as externally to the DALI bus 3 A DALI Short Address Reset command will return the device to Broadcast receive mode and disa...

Страница 8: ...nstallation Setting Operational Modes By default the AL WS DR2C or DR2L operate stand alone no WiFi connection is required For up to 4 standard LEDs with 660 mA each The device is factory calibrated for operation After power up you will see a 2 second ON time with the lights at a very low dim level while it learns the capability of the attached LEDs in your installation After that phase the result...

Страница 9: ... 1 amp Fan and Light operation The On Off switch and slider on the AL WS Bath control the dimming of the attached LEDs The Fan can be turned on with the light at the same time no external switch or it can be operated by the remote switch A red dip switch controls the selection Upgrade any time to full timer based control or add on our Motion sensor for automatic operation and timers ...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Отзывы: