ATX AL-FF-100 Скачать руководство пользователя страница 5

AL-WS-DR2 and AL-WS-DR2C Operation 

 

Momentary or On/Off Main Switch operation 

 

The main switch of the device can be either On/Off type or Momentary.  On/Off has the dimmer on the right, Momentary is 
installed with the dimmer on the left.  The difference is that each press of the Momentary style causes the light to turn On/Off.    
 

Main switch functions – Momentary style 

 
A momentary switch springs back to On when the lever is pressed down, an On/Off does not spring back (On/Off see below)    
When installing a momentary switch type - the slider is on the left and the PCB is upside down.   

Function 

Press 

How to trigger 

 
On / Off 

 

½ second 

 
Push the switch down for under ½ second.   The light will turn on and 
off each time you press. 

 
Reset to defaults: 

Recalibrate the LED currents 
Set switches to On/Off style 

 

60 

 
Press and hold the button for 60 seconds. The switch will enter self 
calibration mode the next time the light is turned on.  The switch 
method will change back to On/Off type. See below.   

 
Restore to Momentary Style 

 

5 times 

½ second 

 
Should the light not stay on when the momentary switch is pressed, 
the device is in Rocker mode – for example after factory default. 
 
Press the button 5 times with less than 0.5 seconds each to change to 
Momentary operation. 

 

Main switch functions – On/Off style 

 
A momentary switch springs back to On when the lever is pressed down, an On/Off switch does not spring back   When 
installing a On/Off switch type, the Slider is on the right. 
   

Function 

Press 

How to trigger 

 

Exit Momentary Style 

Turn ON 

Wait 60 

seconds 

 

Turn OFF 

Should the not act like a simple On/Off switch, then it might be in 
Momentary style.     A Factory reset will fix this. 

Factory reset – press switch top in, wait 60 seconds,  turn switch off. 
 
The device will return to On/Off style and will recalibrate.    

 
Reset to defaults: 

    waiting to calibrate 
    switches are On/Off type 

 

Set the dim to low dim.  Turn the switch on for 2 seconds.  Now off 
and on 8 times, quickly, leaving it on after the last flip.   The brightness 
will change to 50%, then go off 

The switch will enter self calibration mode and the lights will flash.  

 

 

Содержание AL-FF-100

Страница 1: ...le switch found at Home Depot can be used or the AL WS M momentary switch can be used for advanced timer controls Stand alone it operates as a simple switch for 1 strings of LED s and 1 fan Use AWG 16 or 18 to bring 48v or 24 to 52 volts from a central power supply over to the switch then use AWG 20 to connect to your LED and Fan no crimping tools are required to wire this device A proven rocker s...

Страница 2: ...oupled AWG 18 24 gauge wire spring fit short and long addresses 16 to 24 volts 2 mA N Way input Simple contact for Fan control see Software N Way Operations LED output A Top Left LED PIR Fan output B Top Right FAN Timer 0 to 90 minutes using DALI commands Exhaust Fan ATX FAN 12v Description Low noise ceiling wall mount ventilating fan with super low profile rated for continuous running It uses the...

Страница 3: ...Wiring the AL WS DR2 Fan and Light ...

Страница 4: ...watts of LED loads Series LED wiring The LEDs are wired in series The simple strip and poke OJ 606 connectors are easy to install in ceilings If you only cut the Red wire you can save time and work by wiring as shown at left From 1 to 5 LEDs can be connected on each side Set the jumpers for 300 360 660 or 720 mA Note for 6 watt LEDs a 5 in series at 660 mA 51v b 4 in series at 660 mA 48v c 2 in se...

Страница 5: ...change back to On Off type See below Restore to Momentary Style 5 times second Should the light not stay on when the momentary switch is pressed the device is in Rocker mode for example after factory default Press the button 5 times with less than 0 5 seconds each to change to Momentary operation Main switch functions On Off style A momentary switch springs back to On when the lever is pressed dow...

Страница 6: ... the switch on or off It will turn on immediately and stay on 10 minutes after the light is turned off Turn the fan switch off to return to manual mode B Timer If the fan switch is left on then each time the light is turned on after 90 seconds the fan will turn on and stay on for 10 minutes and turn off automatically For momentary switches A Press to start each press adds 5 minutes run time enable...

Страница 7: ...s after provisioning the mechanical front switch in this device is placed into either short address or Group mode see below flipping the switch or the 3 way remote switches or the slider dimming value will cause a DALI command to be sent internally to the LED outputs as well as externally to the DALI bus 3 A DALI Short Address Reset command will return the device to Broadcast receive mode and disa...

Страница 8: ...nstallation Setting Operational Modes By default the AL WS DR2C or DR2L operate stand alone no WiFi connection is required For up to 4 standard LEDs with 660 mA each The device is factory calibrated for operation After power up you will see a 2 second ON time with the lights at a very low dim level while it learns the capability of the attached LEDs in your installation After that phase the result...

Страница 9: ... 1 amp Fan and Light operation The On Off switch and slider on the AL WS Bath control the dimming of the attached LEDs The Fan can be turned on with the light at the same time no external switch or it can be operated by the remote switch A red dip switch controls the selection Upgrade any time to full timer based control or add on our Motion sensor for automatic operation and timers ...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Отзывы: