![ATX AL-FF-100 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/atx/al-ff-100/al-ff-100_manual_3006240006.webp)
AL-WS-DR2 and AL-WS-DR2C
Local Fan Controls
Fan Wiring
A SLM70-LVDC or similar fan can be connected to the Right Led/Fan output. It will be automatically detected and
operation will be in Automatic, manual or timer mode as described below in the N-Way section. The AL-WS-DR2
in fan mode has a 12 volt output and the SLM70-LVDC has a 4400 uf input capacitor that allows it to be
automatically detected. 12 fans will lower capacitance may not be detected.
Fan operation supports two types of switches, and also operation without a fan switch.
For On/Off type switches (not momentary)
A) Manual. In this mode – leaving the fan switch off keeps the fan off. You can turn the fan on/off anytime by
turning the switch on or off. It will turn on immediately and stay on 10 minutes after the light is turned off.
Turn the fan switch off to return to manual mode.
B) Timer. If the fan switch is left on, then each time the light is turned on, after 90 seconds the fan will turn on
and stay on for 10 minutes and turn off automatically.
For momentary switches
A) Press to start: each press adds 5 minutes run time, enables automatic operation
B) Press long to stop: press for 4 seconds and release to stop the fan, disables automatic operation
C) Automatic operation: Each time the light is turned on, after 90 seconds the fan will turn on and stay on for
10 minutes and turn off automatically. Press for 4 seconds and release to stop the fan now and exit
automatic operation.
For operation with no fan switch
A) Wire the N-way pin to the N-way Gnd pin. The fan will operate in Timer mode, otherwise it will not operate.