background image

AL-WS-DR2 DALI Control 

 
DALI is not required for the operation of the AL-WS-DR2 (DALI).   See the AL-WS-DR2 data sheet for 
DALI detailed commands and features. 

By default – the AL-WS-DR2 only responds to DALI broadcast commands – it will not transmit.   There is no group 
or short address assignment.  Since the device accepts DALI broadcast commands – any DALI switch or master 
that sends broadcast commands can connect to this device remotely for on/off/dimming – the LED outputs are 
controlled by the switch or DALI broadcast packets.  In Default mode – no DALI transmissions occur.   DALI 
received commands are treated like 3-way switch controls.  

 

Full DALI Operation  

 

For full DALI operation - connect your powered DALI bus to the DA+ and DA- pins (polarity is not significant ) of the 
AL-WS-DR2.   The device responds to the provisioning commands from a DALI master.   In order for addressable 
functions to work, a ‘short’ address [ 0 thru 63] needs to be assigned.   This can be done by a DALI Master with 
configuration features.  Once a short address is assigned – the device can be understood to operate as two 
devices in one. 
 

1) LED driver with DALI control – the LED outputs will have a unique DALI short address after provisioning.   
The LED driver outputs are connected to LED’s and each switch can now be individually controlled by DALI 
commands from the bus.   All DALI 60929-2006 commands are supported.   The actual address and group 
is defined and can be changed by the DALI master.  See below. 
 
2) Dimmer / Switch with DALI outputs – after provisioning – the mechanical front switch in this device is 
placed into either short address or Group mode – see below –  flipping the switch, or the 3-way remote 
switches, or the slider dimming value will cause a DALI command to be sent internally to the LED outputs 
as well as externally to the DALI bus.     
 
3) A DALI Short Address Reset command will return the device to Broadcast receive mode and disable all 
On/Off/Dim transmissions.  

 

 

 

DALI Address Assignment - Auto - Grouping

  

 
The switch from the factory has no DALI Short address by default.   When a DALI master assigns a short address 
to the switch, one built-in feature rule has been implemented in all DALI ATX-LED devices.     

 

If the short address assigned is from 0-15, then the built-in switch will send a Group On/Off/Dim command 
to the DALI bus each time the local status changes – On, Off, Dim – from the switch, slider or N-Way.  This 
method allows multiple AL-WS-DR2 to be configured as a gang – to all operate as one switch.   After 
assigning each DR2 a short address less than 16, add to each AL-WS-DR2 the group address of the 
others to be ganged together.   An AL-WS-010v can also be assigned to the same group.  

 

If the short address is from address 16-63, then the switch will output these state changes using its short 
address, not a group address:   An AL-WS-010v can be assigned the same short address to implement 3-
way control with dimming. 

 
DALI commands also are used to determine the 3-Way state.   Therefore, a DALI command with the matching 
Group or Individual address will set the light on or off – and all local switches – physical or virtual – will reflect that 
change – so that the next flip of any switch will turn the light off or on as intended.    

Содержание AL-FF-100

Страница 1: ...le switch found at Home Depot can be used or the AL WS M momentary switch can be used for advanced timer controls Stand alone it operates as a simple switch for 1 strings of LED s and 1 fan Use AWG 16 or 18 to bring 48v or 24 to 52 volts from a central power supply over to the switch then use AWG 20 to connect to your LED and Fan no crimping tools are required to wire this device A proven rocker s...

Страница 2: ...oupled AWG 18 24 gauge wire spring fit short and long addresses 16 to 24 volts 2 mA N Way input Simple contact for Fan control see Software N Way Operations LED output A Top Left LED PIR Fan output B Top Right FAN Timer 0 to 90 minutes using DALI commands Exhaust Fan ATX FAN 12v Description Low noise ceiling wall mount ventilating fan with super low profile rated for continuous running It uses the...

Страница 3: ...Wiring the AL WS DR2 Fan and Light ...

Страница 4: ...watts of LED loads Series LED wiring The LEDs are wired in series The simple strip and poke OJ 606 connectors are easy to install in ceilings If you only cut the Red wire you can save time and work by wiring as shown at left From 1 to 5 LEDs can be connected on each side Set the jumpers for 300 360 660 or 720 mA Note for 6 watt LEDs a 5 in series at 660 mA 51v b 4 in series at 660 mA 48v c 2 in se...

Страница 5: ...change back to On Off type See below Restore to Momentary Style 5 times second Should the light not stay on when the momentary switch is pressed the device is in Rocker mode for example after factory default Press the button 5 times with less than 0 5 seconds each to change to Momentary operation Main switch functions On Off style A momentary switch springs back to On when the lever is pressed dow...

Страница 6: ... the switch on or off It will turn on immediately and stay on 10 minutes after the light is turned off Turn the fan switch off to return to manual mode B Timer If the fan switch is left on then each time the light is turned on after 90 seconds the fan will turn on and stay on for 10 minutes and turn off automatically For momentary switches A Press to start each press adds 5 minutes run time enable...

Страница 7: ...s after provisioning the mechanical front switch in this device is placed into either short address or Group mode see below flipping the switch or the 3 way remote switches or the slider dimming value will cause a DALI command to be sent internally to the LED outputs as well as externally to the DALI bus 3 A DALI Short Address Reset command will return the device to Broadcast receive mode and disa...

Страница 8: ...nstallation Setting Operational Modes By default the AL WS DR2C or DR2L operate stand alone no WiFi connection is required For up to 4 standard LEDs with 660 mA each The device is factory calibrated for operation After power up you will see a 2 second ON time with the lights at a very low dim level while it learns the capability of the attached LEDs in your installation After that phase the result...

Страница 9: ... 1 amp Fan and Light operation The On Off switch and slider on the AL WS Bath control the dimming of the attached LEDs The Fan can be turned on with the light at the same time no external switch or it can be operated by the remote switch A red dip switch controls the selection Upgrade any time to full timer based control or add on our Motion sensor for automatic operation and timers ...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Отзывы: