ATTO Technology FibreBridge 4500 Installation and Operation Manual
4.1.2 Diagnostic commands
ATTO FibreBridge
diagnostic commands help validate FibreBridge operation and diagnose/isolate
FibreBridge faults through the Event Log.
Event logging is a mechanism for on-site
observation of internal FibreBridge behavior such
as tracing SCSI commands received over the
Fibre Channel from the host and return of data and
status to the host.
ClearEvent
Clears the contents of the event log.
Actions:
ClearEvent
Information:
none
DispEvent
Sets the switches which control the filtering performed when displaying events.
Limits: To display from several different subsystems or
events, use a mask value equal to the logical OR of the
corresponding values. To display events from all
subsystems, enter [0x7F] as the mask
Default: [0x7F] 0x3F] [all]
[subsystem] controls which subsystem’s events display
0x01 FCP Processor/i960 Interaction
0x02 SCSI Processor/i960 Interaction
0x04 Ethernet
0x08 Extended copy
0x20 NVRAM & Flash
0x40 ECC & Parity
[status] [all]: all events regardless of status values
[ngood]: only events with a status value other than good
[event_level] controls what report level events display
0x01 Info: general information
0x02 Warning: unexpected situation/condition
0x04 Critical: operation limited/curtailed
0x08 Failure: hard failure
0x10:Other
0x20 Debug: ATTO tracking events
Actions:
set DispEvent [subsystem] [event_level]
[status]
Information:
getDispEvent
Verbose return: DispEvent=SubSys:0xXX Lv1:0xXX
Status: [all | no good]
SaveConfiguration
DispFcPortDB
Displays the contents of the specified FC port’s internal port database which contains Fibre Channel addressing information for each FC target
device visible to the FibreBridge.
Action:
none
Information:
DispFcPortDB <fp>
Returns: Node name, 24-bit port ID, 8-bit internal loop ID of each FC
device
DisplayEvent
Results in a display of the current contents of the event log to the display. The log is filtered by the current switch settings as
described in the DispEvent command. If the optional
all
parameter is provided, the display filtering is temporarily suspended and
all logged events are displayed regardless of the current event filter switch settings.
Actions:
DisplayEvent <all>
Information:
none
EccLog
Contains the ECC error statistics for the FibreBridge since the statistics were last cleared. Set form sets the statistics to zero.
Limits: Maximum number of errors reported = 65535
Actions:
set EccLog clear
Information:
get EccLog