31
EN
7.5
REGULATOR CONTROL AND OPERATING MODES
Turning on the controller is signalized by a brief switching on all the light indicators on display
to enable to check their status. If the regulator gets suddenly disconnected from electricity
mains (e.g. by power failure), it is switched to the last mode used, when the failure occurred. All
the settings made are saved even after the power failure.
The basic setting of the controller is the adjustment of the boiler temperature by the knob. Other
functions are controlled adequately to the service parameters set in the service menu.
The boiler is turned on by pressing the START (17) button that starts the fan. The STOP (16) but-
ton switches the boiler off by turning the fan off.
The sign displayed behind the numeric temperature indication (7) is related to the current
mode of the PID PROFI regulator:
[50°-] indicates the stand–by mode
[50 °C] indicates the winter operating mode
[50 °C] indicates the winter operating mode when the boiler temperature is achieved
[50°U] indicates summer operating mode intended only for D.H.W. preparation
[50°u] indicates summer operating mode when the boiler temperature is achieved
[70°d] indicates mode of elimination the legionella bacteria, when the temperature of D.H.W. is
increased to 75 °C
[50°P] indicates that regulator is blocked by pellet burner of the COMBI Pellet boiler
The PROFI PID regulator has an advantage of regulating the flue gas temperature to the required
value. The controller struggles to achieve the adjusted flue gas temperature and after it is
achieved, the required boiler temperature is to be reached. Thereby is the fuel used in the best
way and the high efficiency is achieved.
7.6
SETTING THE USER PARAMETERS
The menu for displaying and setting the user parameters is accessible after short pressing of the
OK button. The „+“ and „−“ buttons are used to browse in settings and parameters. The appro-
priate parameter selected becomes adjustable by the „OK“ button and starts to flicker. Then it
can be changed by the „+“ and „−“ button and confirmed by „OK“. Some of the parameters are
only informative and they cannot be changed. To exit the menu, confirm the [End] by „OK“ but-
ton. After remaining more than 1 minute without the user´s intervention, the controller switches
the display to the basic mode.
Содержание ATTACK DPX 25 COMBI Pellet
Страница 1: ...www attack sk EN 07 2019 ATTACK DPX COMBI PELET Instructions for use EN ...
Страница 2: ......
Страница 66: ...65 EN 13 ELECTRICAL SCHEMES 13 1 ATTACK DPX 25 30 35 COMBI PELLET ...
Страница 68: ...67 EN 13 2 ATTACK DPX 40 45 50 COMBI PELLET ...
Страница 83: ...11 ...
Страница 98: ......
Страница 99: ......