13
EN
2.4.6
CONNECTION WITH EXTERNAL PELLET TANK AND PELLET FEEDER
To the boiler ATTACK DPX COMBI Pellet is recommend to use ATTACK pellet tank in combination
with screwed ATTACK pellet feeder, length about 2 m.
Pellet tank is possible to place on the
right or the left side of the boiler, where necessary. For 30 kW burner there is recommend-
ed PED200 feeder. Feeder PED210 is recommended for 50 kW burner
. Between hole of
feeder and delivery tube on the burner should be a height difference at least 300 mm. In the
horizontal direction should be space between the hole of feeder and delivery tube at least 150
mm (i.e. not vertically aligned).
Before first starting up of the burner it is necessary to make setting of feeder (p. 58). For setting
of the feeder it is necessary to load the pellet tank with sufficient amount of pellets and load the
pellet feeder with connection to the mains until the pellets begin falling down of the top hole of
the feeder. Connect the feeder to the burner outlet. After correct setting of the feeder, install the
inlet hose between the outlet tube of feeder and the delivery tube of burner and adjust the
length of the hose. The hose should not be straight and also not so bented to prevent the pellets
inside of stacking and accumulating.