37
139435_A GZ
455
DV 8/28/12
10.0
Appendix
Access Panel
Support
Bracket
Hex Nuts
Retainer Bar
This blower must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the current
ANSI/NFPA 70, National Electrical Code or CSA C22.1-Canadian
Electrical Code.
Be certain the blower motor is securely fastened to the
mounting frame on the stove.
Always disconnect the power supply to the stove before
performing any service on the blower.
Contents
• Blower Assembly - Less than .83 AMPS, 12VAC, 60Hz
• #8 x 1/2” sheet metal screws, 3
Tools Required
• 10 mm socket • ratchet
• 1/4” nut driver • Safety gloves
• Safety glasses
Installation from Back of Cabinet
1. Use a 1/4” nut driver or socket to remove
e
ight
#8 x 12 sheet metal screws and the Rear Access
Panel. See fig. 10.1.
2. Use a 10 mm wrench or socket to loosen two M6
flange nuts and remove the Retainer Bar from
the Support Bracket.
3. Attach the Retainer Bar to the Blower body using the
three #8 x 1/2” sheet metal screws supplied.
4. Engage the Blower Retainer Bar slots with the
flange nuts and tighten the nuts.
5. Route the blower power cord around to the FCM.
6. Replace the Rear Blower Access Panel.
7. Plug the power cord into the FAN outlet on the FCM.
DO NOT SWITCH THE FCM “ON” UNTIL
FIREPLACE INSTALLATION IS COMPLETE.
10.1 Blower Installation
Read these instructions before beginning the installation.
If the fireplace has already been installed, the blower may
be installed from the front as noted below.
This accessory operates in conjunction with the Remote
Transmitter. See the operation instructions included with
the transmitter kit and the appliance Owner’s Manual.
Figure 10.1
Installation from Front of Cabinet
1.
Disconnect the power supply from the fireplace.
Switch the FCM to OFF.
2. Remove the apron panel from the cabinet front
to access the control compartment.
3. Remove the two wing nuts that secure the
controls compartment base to the fireplace
cabinet. Fig. 10.2.
Swing the compartment assembly out to access the back
of the cabinet.
4. Follow Steps 2, 3, and 4 above.
5. Relocate the compartment assembly back into position and
route the blower power cord around the side to the FAN
outlet on the FCM. Replace the compartment wing nuts.
6. Re-connect power supply to the fireplace and switch the
FCM to ON.
Wing
Nut
Controls Compartment
Figure 10.2