17
139435_A GZ
455
DV 8/28/12
6.0
Fireplace Assembly
6.1 Glass Frame Removal
The glass frame is removed by disengaging six
compression latches. There are two upper, two lower, and
one at each side. See fig. 6.1. Simply pull the latch handle
out to release each latch. Disengage the lower and side
latches before releasing the upper latches.
6.2 Routing the Power Supply
Figure 6.2. Hard wiring at the junction box. See also electrical wir-
ing diagram, Appendix 10.3, page 38.
HARD WIRING REQUIREMENT
As this appliance is permanently framed into an
enclosure, it must be hard wired to 120 VAC house
current at the fireplace junction box located at the
right rear corner of the cabinet.
This fireplace must be electrically connected
and grounded in accordance with local codes. In
the absence of local codes, use the current ANSI/
NFPA 70-1996 NATIONAL ELECTRICAL CODE IN THE
U.S. OR CSA C22.1 CANADIAN ELECTRICAL CODE for
Canada.
The leads inside the junction box are connected to the Fan
Control Module (FCM) which controls power to the burner
ignition system, blower, and accent lamps.
CAUTION!
CONFIRM THAT THE FCM POWER SWITCH IS IN THE OFF
POSITION BEFORE TURNING POWER ON TO THE FIREPLACE
AT THE SERVICE BOX. See fig. 6.18, page 25. DO NOT TURN
THE FCM ON UNTIL UNTIL THE INSTALLATION IS COMPLETE
AND YOU ARE READY TO INITIATE THE FIRST BURN.
1. Remove the cover plate from the junction box and
attach the cable clamp from the Hardware bag.
2. Use wire nuts to connect the house current wires to the
black and white leads as indicated in fig. 6.2.
3. Connect the cable ground wire to the grounding
terminal in the fireplace base.
4. Replace the junction box cover plate and secure the
cable clamp to the cable.
WHITE
BLACK
GROUND
GREEN
BLACK
WHITE
Power
Receptacle
Assembly
157028
Figure 6.1.
Disengage the Glass Frame latches.