6.5.1 Fuel Conversion Procedure
1. Turn off gas supply
to the appliance and disconnect
from electrical power source.
3. Remove the Front Apron
panel (fig. 6.5-A).
Use a 1/4” socket driver to remove the two side screws
and only loosen the five bottom screws.
4. Remove the Controls Heat Shield
(fig. 6.5-B).
Reach under the firebox to loosen the
Air Shutter wing
nut
located above the valve compartment (fig. 6.6).
5. Lift the Burner Riser/Media Tray
(fig. 6.5-C) out of the
firebox.
6. Remove the Burner plate,
lifting it up and to the right
to disengage it from the support brackets and air
shutter.
7. Change the Air Shutter orientation.
Flip the shutter
over to indicate the appropriate fuel. See fig. 6.7.
8. Change the Burner Injector.
See fig. 6.8. Using a
1/2” open end wrench or deep-well socket remove
the burner orifice from its brass elbow housing and
replace with the appropriate orifice supplied in the kit.
9. Change the Pilot Orifice:
Fig. 6.8. Use a small blade
screwdriver to release the retainer clip and pull the pi-
lot hood off of its base. Use the 4mm hex key supplied
to remove the pilot orifice from within the base and
install the new orifice from the conversion kit.
Figure 6.8.
Burner Injector and Pilot orifice replacement.
Pilot Hood
Pilot Orifice
Injector
Air Shutter
Figure 6.6. Air Shutter Stem wing nut located above valve.
Air Shutter Stem
Figure 6.5.
Firebox panels and riser assembly removal.