3
139435_A GZ
455
DV 8/28/12
Table of Contents
1.0
Specifications ...................................................
4
2.0 General Information....................................... 5
3.0 Safety Information .........................................6
4.0 Installation Requirements
4.1 Electrical Requirements
......................... 7
4.2 Fireplace Location
................................... 7
4.3 Framing Requirements
...........................8
4.4 Surround Treatments
............................. 11
4.5 Vent Framing Requirements
...............12
4.6 Hearth Requirements
..........................12
4.7 Fireplace Clearances
.............................12
5.0 Venting Requirements
5.1 Horizontal Termination .........................13
5.2 Vertical Termination
...............................15
5.3 Exhaust Restriction
................................15
5.3 Intake Restriction
...................................15
6.0 Fireplace Assembly
6.1 Glass Frame Removal
............................17
6.2 Routing the Power Supply
...................17
6.3 Gas Connection
.......................................18
6.4 Gas Pressure
........................................... 19
6.5 Fuel Conversion
.................................... 19
6.6 High Altitude Adjustment
...................21
6.7 Firebox Panel Installation .................... 22
6.8 Burner Media ......................................... 23
6.9 Surround Facing Assembly ................
24
6.10 System Check
....................................... 25
6.11 Initial Operation Notes ........................26
7.0 Operation
7.1 SIT Proflame System Features ............ 27
7.2 Control Functions
................................... 27
8.0 Maintenance
8.1 Annual Cleaning
......................................31
8.2 Glass Care
.................................................31
8.3 Gasket Inspection ..................................31
8.4 Glass & Gasket Replacement
.............31
8.5 Battery Replacement
........................... 32
8.6 Accent Lamp Replacement
................. 32
9.0 Illustrated Replacement Parts
...........
34 - 36
10.0 Appendix
10.1 Blower Installation ............................... 37
10.2 Approved Vent Manufacturers
.........38
10.2 Mobile Home Installation ..................38
10.3 Wiring Diagram ...................................38
11.0 Warranty Statement ..................................
42
12.0 Lighting Instructions
..................................
43
Unpacking the Fireplace
1. Inspect the fireplace for damage
. Immediately report any
damage to your dealer.
2. Confirm contents.
The Atra GZ
455
DV Fireplace includes the following items
shipped inside the firebox and Miscellaneous Hardware bag:
• Simpson Dura-Vent 5” x 8” to 4” x 6 5/8” Vent Reducer
• 4 mm hex key
• Remote Control Transmitter and Wall-mount Bracket
• Non-metallic sheath cable clamp
• Propane Fuel Conversion Kit
3. Confirm Firebox Components.
The firebox accessories have been packed in separate boxes,
and may include one or more of the following items:
Face Plates: 37” x 23”
(94 cm x 58.4 cm)
• 157418 - Black Powder Coat
• 157419 - Bronze Powder Coat
• 157420 - Iron Age Powder Coat
• 157421 - Stainless Steel
Backer Plates: 43” x 30 3/8”
(109.2 cm x 77.1 cm)
• 157422 - Black Powder Coat
• 157423 - Stainless Steel
Liner Treatments
:
• 157413 - Mirror Liner
• 157414 - Black Reflective Liner
• 157407 - Desert Sand Stucco Refractory Liner
Burner Treatments
:
• 157415 - Clear Glass Embers
• 157416 - Black Glass Embers
• 157417 - Tumbled Stones / 125 pcs.
4. Confirm Fuel Type.
This fireplace has been factory-configured to burn Natural
Gas. Be sure that the correct fuel source is available for this
appliance.
5. Detach Pallet Brackets -
one at each side.
6.
Detach the
Stand-off Brackets
from each side of
the cabinet and
re-install them
oriented 180° with
the nailer flange
facing forward.
Bend each flange
90° to the side.
See also Fig. 4.3.