30. Possible failures and troubleshooting
Failure Reason Solution
The “mains” indicator not lit
up
- no voltage in network
- plug incorrectly inserted to el.
socket
- defective power supply switch
- defective electric cord
- check
- check
- replace
- replace
Boilers do not reach their re-
quired outputs and the pre-set
water temperature
- not enough water in the sys-
tem
- excessive pump output
- the boiler output is not suffi
-
ciently rated for the particular
heating system
- low quality fuel (high level of
moisture, large pieces)
- ignition valve leaking
- insufficient chimney draught
- excessive chimney draught
- insufficiently cleaned boiler
- combustion-air inlet to load-
ing chamber is clogged
- refill
- adjust the pump’s switching
and flow rate
- design issue
- burn good quality coal and
dry wood; split logs in half
- repair
- new chimney; unsuitable con-
nection
- change the primar air setting
- place a throttle valve (draught
limiter) in the flue-gas duct
- clean
- clean
Door leaking
- defective fibreglass cord
- the nozzle becomes clogged
- insufficient chimney
- replace
- adjust the door hinges
- do not burn small-particle
wood, sawdust, bark
- chimney defect
Ventilator does not turn
- boiler overheated
- safety thermostat fuse inter-
rupted
- rotating wheel clogged
- defective capacitor
- defective motor
- press the thermostat push-but-
ton (using a pen)
- clean the ventilator including
the ducting from tar and sedi-
ments
- replace
- replace
- check - measure