Control panel appearance
Description:
1.
Thermometer
– indicates the temperature of water exiting the boiler
2.
Main switch
– used to completely shut down the boiler
3.
Waste gas thermostat
– is used to switch off the ventilators when the waste gas temperature
drops – after the fuel has burnt out. The boiler-circuit pump stops operating simultaneously with
the ventilators.
CAUTION
– when firing up (igniting), set the waste gas thermostat to (‚‘0 °C“- firing-up).
After flaring up, set the waste gas thermostat to „operation“ position. The user needs to de-
termine the optimal operating position for particular conditions. Should the waste gas tem-
perature fall below the preset value, the thermostat switches the ventilator off. If you want
the ventilator to start operating again, set a lower temperature on the waste gas thermostat
(e.g. set it to „0 °C“ - firing-up).
4.
Control thermostat no. 1 (boiler thermostat)
– controls the first ventilator operation depending
on the temperature of water exiting the boiler. Set it to temperature of 85 - 90 °C.
5.
Ignition valve pulling-rod
– is used for opening up the ignition valve during ignition or fu-
el-loading stage.
6.
Control thermostat no. 2 (boiler thermostat)
– controls the second ventilator operation depend-
ing on the temperature of water exiting the boiler. Set it to temperature of 80 - 85 °C.
7.
Pressure gauge
– indicates the current pressure of water in boiler.
8.
Safety irreversible thermostat
– serves as boiler protection against overheating in case of con-
trol thermostat failure or as an indication of exceeding the emergency temperature. If such exceed-
ing occurs, it is then necessary to depress the thermostat.
9.
Area for electronic regulation
of the heating system can be used to house any type of regulation
system that fits into an aperture of 92x138 mm. The electric harness is prefabricated and ready to
be used for the regulation’s power supply.
Advantages of the boilers
The burning happens at very high temperatures with a generator-gasification function. This fea-
ture means fuel savings and environmentally friendly operation. The boilers have the primary and
secondary air pre-heated to a high temperature. Therefore, they are characterised by a warm and sta-
ble flame with consistent combusting quality. The large feeding hopper allows burning of large wood
logs and splits up to 550 / 750 mm max. length. The boilers are fitted with a cooling loop protecting
it against overheating and with two thermostats for switching the boiler-circuit pump.
1. Outgoing water thermometer
2. Main switch
3. Waste gas thermostat
4. Operating thermostat of the ventilator no. 1
5. Ignition valve control
6. Operating thermostat of the ventilator No. 2
7. Pressure gauge
8. Safety thermostat
9. Area for electronic regulation of the heating
system (92x138 mm)
1
0
2 8
1
4
6
9
3
5
7