AT-OME-MS42
76
Solution Setup and Configuration Guide
5.
Login to the web server. Refer to
Introduction to the Web Server (page 51)
.
6.
Click
RS-232
in the menu bar.
7.
Set the RS-232 settings for the display (sink) device, under the
RS232 over HDBaseT
section. These settings
must match the device settings for the display. Refer to the User Manual of the display device for more
information.
8.
Click the
Save
button to commit changes.
9.
RS-232 pass-through configuration is complete. The control system can now be used to send commands to
the connected display device. Use the following API command to send a command to the display (sink) device,
where
display_command
is the command data to send:
RS232Zone[display_command\x0d]
\x0d
(carriage return) should only be added to end of the string if the sink device is expecting this character.