- 34 -
Setting pre-settings
By pressing button (1) once, twice or three times
you will select pre-set time 1, 2 or 3.
The display shows e.g. pre-set time 1 and symbol
1. Set the pre-set period with buttons (2) or (3).
With button (4) you can activate or deactivate the
pre-set period. When activated the symbol "ON"
appears and the symbol "1, 2 or 3".
Operation
Switching ON the heater
Press button (4). The heating period lasts
..minutes. The display shows: remaining heating
time and symbol 7.
Switching OFF the heater
Press button (4). The heater will run idle for about
3 minutes. The display shows: actual time.
Continuous operation
Press and hold button (3), then press button (4);
now the heater will be operating till button (4)
(heater off) is pressed.
Activating/ deactivating pre-set time
Select pre-set time 1, 2 or 3 by pressing button (1).
Activate the selected time by pressing button (4).
The display shows: symbol "ON" as well as the
selected pre-set time, "1, 2 or 3".
BEFORE STARTING
1. Before initial start-up, prepare battery for
operation if not already done. See section
2. Check that the draining caps in the spillage-free
frame are firmly tightened.
3. With the compressor standing level, check the
level of the engine oil. Add oil, if necessary, to the
upper mark on dipstick. Also check the engine
coolant level. Consult the Engine Operation
Manual for the type of coolant and type and
viscosity grade of the engine oil.
4. Remove the air receiver drain plug (1), see figure,
and open the valve to drain possible condensate.
Close the valve when oil comes out and reinstall
the drain plug. The interval between draining
operations may be determined by experience, as
the amount of condensate depends on the
operating condition.
5. Check the level of the compressor oil. See section
. The pointer of oil
level gauge (OLG) should register in the green
range. Add oil if necessary. See section
for the oil to be used.
6. Check that the fuel tank contains sufficient fuel.
Top up, if necessary. Consult the Engine
Operation Manual for the type of fuel.
7. Drain any water and sediment from the fuel filters
until clean fuel flows from the drain cock.
8. Empty the dust trap of each air filter (AF). See
Replacing the filter element and the
The preheating time at -25°C is about 90
minutes.
(1)
(2)
Before draining, ensure that the
pressure is released.
Before removing oil filler plug (FP),
ensure that the pressure is released by
opening an air outlet valve.
Содержание XRHS 1150 CD4 C3 WUX
Страница 2: ......
Страница 16: ... 16 Main parts ...
Страница 18: ... 18 REGULATING SYSTEM ...
Страница 21: ... 21 ELECTRIC SYSTEM 9822 0963 40 C13 HP ...
Страница 104: ... 104 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 105: ......
Страница 106: ...www atlascopco com ...