SOOT LOAD reaches 90% (only when DPF
Regeneration is Inhibited)
When still no DPF regeneration is forced the next
warning alarm will pop-up:
Required Action:
Acknowledge the ‘PLEASE FORCE DPF
REGENERATION !’ warning (press Enter while
in the Main View).
Force DPF Regeneration, see paragraph
FORCE
DPF REGENERATION
When DPF Regeneration is started, the DPF
Regeneration Needed icon will disappear and the
HEST icon will pop-up.
SOOT LOAD reaches 92%
When still no DPF regeneration is forced the next
warning alarm will pop-up.
Additionally the machine will be prevented to Load:
Required Action:
Acknowledge the ‘LOAD PREVENTION -
HIGH DPF SOOT LOAD’ inhibit load alarm
(press Enter while in the Main View).
Force DPF Regeneration, see paragraph
FORCE
DPF REGENERATION
When a DPF Regeneration is started, the DPF
Regeneration Needed icon will disappear and the
HEST icon will pop-up.
SOOT LOAD reaches 95%
If still no action is taken the following warning
appears and the controller will perform a controlled
shutdown.
As soon as the engine is stopped, the DPF
Regeneration Needed icon will disappear (engine
electronics are powered down)..
DPF Regeneration needed
MAIN VIEW
LOADED
18.6
7130 PLEASE FORCE DPF REGENERATION !
DPF Regeneration needed
MAIN VIEW
LOADED
18.6
7110 LOAD PREVENTION - HIGH DPF SOOT LO...
Contact Atlas Copco for further actions
to be taken.
MAIN VIEW
SHUTDOWN
18.6
7120 SOOT LOAD TOO HIGH - CALL ATLAS CO...
Содержание XRHS 1150 CD4 C3 WUX
Страница 2: ......
Страница 16: ... 16 Main parts ...
Страница 18: ... 18 REGULATING SYSTEM ...
Страница 21: ... 21 ELECTRIC SYSTEM 9822 0963 40 C13 HP ...
Страница 104: ... 104 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 105: ......
Страница 106: ...www atlascopco com ...