8
Technical data
8.1
Readings on control panel
Description
The readings mentioned below are valid under the reference conditions (see section
Reference conditions and limitations
).
Gp
Air outlet pressure
Reading: modulates between preset starting pressure and stopping pressure. See
section
Gd
Dew point temperature
Reading: approx. 2 - 5 ˚C (35 - 41 ˚F). See section
P1
Hour meter
Reading: total running time
Q1/H1
On/off switch with lamp
8.2
Electric cable size
Attention
Local regulations remain applicable if they are stricter than the values proposed below.
The voltage drop must not exceed 5% of the nominal voltage. It may be necessary to
use cables of a larger size than those stated to comply with this requirement.
Cable size
SF 1
SF 2
SF 4
SF 6
Frequency
Voltage
Cable size
Cable size
Cable size
Cable size
IEC
50 Hz
200 V 3~
--
--
6 mm
2
6 mm
2
50 Hz
230 V 1~
4 mm
2
6 mm
2
--
--
50 Hz
230 V 3~
--
4 mm
2
6 mm
2
6 mm
2
50 Hz
400 V 3~
--
1.5 mm
2
1.5 mm
2
2.5 mm
2
50 Hz
400 V 3~ + N
--
1.5 mm
2
1.5 mm
2
2.5 mm
2
Instruction book
2920 7110 11
41