![Atlas Copco SF 1 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/atlas-copco/sf-1/sf-1_instruction-book_3001691030.webp)
Period
(note 1)
Running
hours
(note 1)
Operation
Every 6
months
(note 2)
--
Compressors with integrated dryer:
• If dirty, brush or blow off the finned surface of the dryer's condenser.
• Inspect and clean the electronic drain:
• Functioning of the drain can be checked by pushing the
TEST
button of the drain.
• Cleaning of the drain filter can be done by opening the manual
drain valve during a few seconds.
Yearly
2500
• Replace the air inlet filter(s) (AF) and the prefilter mats on the cooling air
intake openings (if fitted) (note 2).
• Test the safety valve.
• Have temperature protection and motor overload tested.
• Check tension and condition of the V-belt(s).
Every 2
years
5000
• Replace the V-belt(s).
• Replace check valve.
Every 2
years
5000
8 bar and 116 psi compressors:
Have the orbiting scroll bearing greased (see note 3).
Every 2
years
5000
10 bar and 145 psi compressors:
• Replace the element outlet pipe and the plastic insert. See section
.
(Only on SF 1, SF 2 and SF 4)
• Clean fan (FN1 - see
), fan duct and element cooling fins
(see note 2).
• Have orbiting scroll bearing and pin crank bearings greased (see note 3).
• Replace tip seals and dust seal (see also note 4).
Every 4
years
10000
8 bar and 116 psi compressors:
• Replace the element outlet pipe and the plastic insert. See section
.
(Only on SF 1, SF 2 and SF 4)
• Clean fan (FN1 - see
), fan duct and element cooling fins
(see note 2).
• Have orbiting scroll bearing and pin crank bearings greased (see note 3).
• Replace tip seals and dust seal (see also note 4).
Notes:
1. Maintenance must be done according the number of running hours or according the running period,
whichever comes first.
2. More frequently in a dusty environment.
3.
Important note:
Greasing of the bearings of the compressor element must be done with
special
grease
, a
special grease gun
and according a
specific procedure
.
In high ambient conditions, the bearings must be greased more frequently: for every 5 °C (9 °F)
increase above 30 °C (86 °F), the maintenance interval should be reduced with 30 %.
Contact your supplier for details.
4. In extremely dry conditions (relative humidity below 15 %), the tip seals and dust seals need to be
replaced more frequently.
Instruction book
28
2920 7110 11
Содержание SF 1
Страница 1: ...Atlas Copco Oil free scroll compressors SF 1 SF 2 SF 4 SF 6 Instruction book ...
Страница 2: ......