- 69 -
Electrical system
12 Vdc
12 Vdc
Emission compliance
EU STAGE II
Power circuit
Circuit-breaker, 3-ph.
Number of poles
4
4
Thermal release It (thermal release is higher at 25°C)
20 A
20 A
Magnetic release Im
3..5xIn
3..5xIn
Circuit-breaker, 3-ph., lower voltage (optional)
Number of poles
3
4
Thermal release It (thermal release is higher at 25°C)
32 A
40 A
Magnetic release Im
3..5xIn
3..5xIn
Circuit-breaker, 1-ph. (optional)
Number of poles
2
2
Thermal release It (thermal release is higher at 25°C)
40 A
40 A
Magnetic release Im
3..5xIn
3..5xIn
Fault current protection
Residual current release IDn
0.030-30 A
0.030-30 A
Insulation resistance (optional)
10-100 kOhm
-
Outlet sockets
domestic (1x) (optional)
-
2p + PE
16 A 230 V
CEE form (1x)
3p + N + PE
16 A 400 V
CEE form (1x)
3p + N + PE
32 A 400 V
Unit
Dimensions (LxWxH)
1780 x 850 x 1172 mm
1780 x 850 x 1172 mm
Weight net mass
653 kg
653 kg
Weight wet mass
766 kg
766 kg