12
PAGE
Repair Instructions No.189.03/01
PHE 45 S
Mounting the
holding grip
1
Push the clamping plate (5) over the neck
of the machine.
2
Insert the nut (6) into the clamping
plate (5).
3
Push the pin (4) through the clamping
plate (5) and the nut (6).
4
Fit the plastic holder (7) to the machine
and secure it with the O-ring (8) and the
locking ring (9).
5
Screw down the holding grip (1).
6
Push the holding device (3) over the depth
gauge (2).
7
Fit the depth gauge (2) with the holding
device (3) to the machine (see arrow in il-
lustration).
Test Run
Electrical Test
Test run the machine and pay attention to noises.
Let the machine run-in.
Perform an electrical test on the machine (see chapter Electrical and Mechanical Test Instructions).
1
6
5
4
3
2
7
8
9
11
Содержание PHE 45 S