3.2
Digital output contacts
Warning
Voltage-free outputs may only be used to control or monitor functional systems.
They should NOT be used to control, switch or interrupt safety related circuits.
Stop the compressor and switch off the supply before connecting external equipment.
Check the
Connections for external equipment
The Elektronikon (Mk5) always comes with expansion module IO2 that has a number of digital
output contacts which can be used to connect external equipment.
Depending on the optional equipment, extra expansion modules are added to the machine
configuration (IO2, IO34).
Expansion Module IO2 for Elektronikon (Mk5)
The digital output contacts have following specifications:
Relay
Connector
Maximum load
K01
3 X 31
15 A / 250 V AC
15 A / 30 V DC
RC* protected
K02
3 X 31
15 A / 250 V AC
15 A / 30 V DC
RC* protected
K03
3 X 31
15 A / 250 V AC
15 A / 30 V DC
RC* protected
Instruction book
22
APF219617