2. Remove the oil filler plug.
3. Fill the air receiver with oil until the level reaches the filler opening.
4. Refit and tighten the oil filler plug.
5. Run the compressor loaded for a few minutes to allow the oil cooler by-pass valve to open.
6. Stop the compressor and wait a few minutes.
7. Depressurize the system by unscrewing the oil filler plug only one turn to permit any
pressure in the system to escape.
8. Remove the oil filler plug again and top up the air receiver with oil until the level indicator
reaches the right level (pointer in the green range).
9. Tighten the oil filler plug.
10. After carrying out the service actions of the related service plan, the service warning must be
reset.
Resetting the service warning
Control panel
Resetting the Elektronikon regulator:
After carrying out all service actions in the relevant Service Plan, reset the service warning as
follows:
1. Starting from the main screen: move the cursor to the action button -Menu- and press enter
key (10).
Following screen appears: