7.4
Safety valve
Warning
Stop the compressor and switch off the voltage. The operator must apply all relevant
Never run the compressor without safety valves.
No adjustments are allowed.
Testing
The valve can be tested on a separate compressed air line.
Consult your Atlas Copco Customer Centre if the valve does not open at the correct pressure
(see section
7.5
Motor current readout
General
This compressor is equipped with a current meter to measure the main motor current. This
current can be checked on the controller. This current can also be read through a 4-20 mA signal.
Notes
The measuring device is located within the motor's delta configuration. The controller
will calculate and display the corresponding supply current.
Preparation
Two settings determine the displayed current on the controller:
• The dial settings on overload F21: CLASS/I
e
and %xI
MAX
.
• A programmed setting in the controller.
Instruction book
80
APF219617