Reference
Description
8
Cooling water inlet pipe.
Fit a water shut-off valve and water drain valve in the compressor water inlet pipe and
outlet pipe.
Remove the plastic plugs (if provided) from the compressor water pipes and connect the
pipes to the cooling water circuit.
If water shut-off valves are installed, a safety device with set pressure according to the
maximum cooling water inlet pressure has to be installed between the compressor water
outlet pipe and the shut-off valve. When operating the unit, the operator must ensure that
the cooling water system cannot be blocked.
9
Cooling water outlet pipe.
10
Motor ventilation air inlet
11
Compressor air inlet
See the compressor installation manual for more information.
All pipes must be installed stress free to the compressor unit.
For maintenance purpose the cooling water in- and outlet have to be provided with
shut-off valves.
4.3
Electrical connection
Attention
For the selection of the correct cables, see section
Instruction book