2.5 Cooling water requirements
The cooling water quality must meet certain minimum
requirements.
No general recommendation can encompass the effects of all
combinations of the various compounds, solids and gases
typically found in cooling water in interaction with different
materials.
This recommendation is a general guide line for acceptable
coolant quality.
2.5.1Type of the system
Closed system
In a closed system, the same cooling water is circulating through
a system without contact with air.
Open system
An open system is a pass through system, or a circulating system
with a cooling tower. In the latter case, the composition of the
water that enters the cooler must be considered, and not the
composition of the make-up water. Due to the evaporative effect
in the cooling tower, much higher concentrations of ions can
be obtained in the circulating water than in the make-up water.
Fig. 2.6 Pictographs, other locations (typical examples)
13
Automatic condensate drain
14
Automatic condensate drain for optional oil/water
separator (type OSD)
15
Manual condensate drain
16
Stop the compressor before maintenance or repair
17
Warning: under tension
18
Read Instruction book before starting the compressor
19
Switch off the voltage and depressurize the compressor
before maintenance or repair
20
Before connecting the compressor electrically, consult
the Instruction book for the motor rotation direction
21
Torques for steel (Fe) or brass (CuZn) bolts
22
Consult the Instruction book before greasing
23
Switch off the voltage before removing the protecting
cover inside the electric cabinet
24
Oil the gaskets, screw on the filters and tighten by hand
(approx. one half turn)
25
Consult the Instruction book before maintenance or
repair
26
Cooling water inlet
27
Cooling water outlet
28
Oil outlet
Figs. 2.5 and 2.6 Pictographs
Содержание GR110
Страница 6: ...2920 1449 00 6 Instruction book Fig 1 4 GR Full feature during unloading ...
Страница 7: ...2920 1449 00 7 Instruction book Fig 1 5 GR Full feature during loading ...
Страница 14: ...2920 1449 00 14 Instruction book Fig 2 2 Dimension drawing GR110 W up to GR200 W ...
Страница 15: ...2920 1449 00 15 Instruction book Fig 2 3 Installation proposal 2 2 Installation proposals Fig 2 3 ...