Turn the ADJUST KNOB (10) counterclockwise to remove it from the inlet tube. Remove and
discard the O-ring (11).
The balancing chamber (12), spring (13) and poppet (15) are removed at this time. They will
often fall out if the adjust tube is tipped on its end.
Remove and discard the O-ring (17) from the outside of the inlet tube (18).