Work the lever up and down a few times while the regulator is pressurised by purging.
Each time the lever is released, no air hissing should be heard.
After reaching the proper pressure setting, push the purge cover on the second stage again
several times and watch how the intermediate pressure reading responds. When the purge
cover on the second stage is depressed, the intermediate pressure reading will drop. When
the purge cover is released the pressure should return immediately to the proper lock-up
pressure and stay there.
Turn the air off and release all air of regulator set. Loosen and remove the ADJUST TOOL.
Replace the hose and torque to specified torque (3-4Nm)