Use the ADJUST TOOL to insert the orifice into the inlet tube.
Turn adjust knob left so the adjust knob is set in minimum position. Adjust knob keep on
“Min”. Adjust the orifice (22) with the ADJUST TOOL. It is important that the final adjustment
leaves the lever with about 1/8” (3.2 mm) free movement at the end, to allow for the natural
wear of the LP seat (16) during the use of the regulator. Adjust the orifice (22) in, while
moving the end of the lever up and down with the tip of your finger. When the orifice is too
far out you will feel a firm springiness with no free movement. When the seat is too far in
you will feel a great deal of looseness at the end of the lever. You want the orifice (22) to be
positioned so that you feel the 1/8” (3.2 mm) free play when you move the tip of the lever
with your finger.
Содержание Splash Tech R60 2nd Stage
Страница 1: ...2nd Tech R60 2nd Stage Service Manual TECH R60 2nd STAGE...
Страница 14: ...Remove the DIAPHRAGM WASHER 7 and the diaphragm 6 from the housing 3...
Страница 29: ...Install a new well lubricated O ring 11 onto the ADJUST KNOB 10...
Страница 39: ...Re check work of breathing Replace mouthpiece with cable tie...