Line
Function
6HWWLQJUDQJHRUGLVSOD\
6HWWLQJ
increment
%DVLFVHWWLQJ
6420
S
H33 input function (=H4)
1... 26
Switching
of heating
FLUFXLW'+:
operation
6421
S
Contact action direction H33
Rest contact,
Working contact
Operation
contact
/3%QHWZRUN
6600
S
Function not used
1
Error
6711
U
Heat pump reset
No, Yes
No
6800
S
History 1
Date, Time, Error code
6802
S
History 2
Date, Time, Error code
6804
S
History 3
Date, Time, Error code
6806
S
History 4
Date, Time, Error code
6808
S
History 5
Date, Time, Error code
6810
S
History 6
Date, Time, Error code
6812
S
History 7
Date, Time, Error code
6814
S
History 8
Date, Time, Error code
6816
S
History 9
Date, Time, Error code
6818
S
History 10
Date, Time, Error code
0DLQWHQDQFH6SHFLDORSHUDWLRQ
7070
S
Time interval for the maintenance of the heat pump 0... 240
1 month
--
7071
S
Operating time of the heat pump since last
maintenance. Reset? (return to zero) No, Yes
0... 240
1 month
0
7073
S
Mean number of compressor start up operations
per hour of operation, over the last 6 weeks.
Reset? (return to zero) No, Yes
0... 12
0
7141
U
Backup operation
Stop, Start
Stop
Stop: The heat pump is operating normally (with the boiler if necessary).
Start: The boiler is operating on its own,
7142
S
Backup service operating type
Manual, Automatic
Manual
Manual: The emergency operation is not activated when there is a fault (emergency operation = Stop).
Automatic: The emergency operation is activated when there is a fault (Emergency operation = Start).
7150
I
Simulation of outdoor temperature
-50... 50 °C
0.5
--
7HVWRILQSXWVRXWSXWV
7700
I
Test of relays
0
This test consists of commanding the regulator relays one by one and checking the outputs. This permits a check that
the relays are operating and that the wiring is correct (for this, check that each appliance is operating on the installation).
(0) No test, (1) All STOP, (2) Relay output QX1 : heating circuit circulator CC2 (main régul. board), (3) Relay
output QX2, (4) Relay output QX3 : Boiler RLV contact, (5) Relay output QX4 : direct valve. DHW, (6) Relay output QX5,
(7) Relay output QX6 , (8) Relay output QX31 : mixer valve opening (Y1), (9) Relay output QX32 : mixer valve closure
(Y2), (10) Relay output QX33 : heating circuit circulator CC1, (11) Relay output QX34, (12) Relay output QX35 : swimming
pool directional valve, (13) Relay output QX21 module 1, (14) Relay output QX22 module 1, (15) Relay output QX23
module 1, (16) Relay output QX21 module 2, (17) Relay output QX22 module 2, (18) Relay output QX23 module 2,
(19) not used, (20) not used, (21) not used.
The display shows the "key" symbol. By pressing the Info button, "error 368" is displayed.
:DUQLQJ'XULQJWKHWHVWWKHFRPSRQHQWWHVWHGLVHOHFWULFDOO\SRZHUHG
7710
I
Test on output UX1
0... 100%
1
--
7712
I
Signal PWM UX1
0... 100%
1
--
7716
I
Test on output UX2
0... 100%
1
--
Installation and commissioning instructions "1485 - EN"
- 57 -
Heat pump alféa hybrid duo gas