3.4
6HWWLQJWKHFRPEXVWLRQSDUDPHWHUV
during a gas check
To carry out the combustion checks (during a gas
change or during maintenance), the gas generator can
be started independently of the heat pump (
¿JXUH
)
.
"
During each intervention on the electrical
FDELQHWPDNHVXUHWKDWWKHHOHFWULFLW\VXSSO\LV
disconnected.
- Open all the heating circuit valves.
"
:LWK XQGHUÀRRU KHDWLQJ FLUFXLW DQG FLUFXLW
NLWZLWKYDOYH&ORVHWKHPL[HUYDOYHE\KDQG
3.4.1 Heating installation with radiators
1
- If the directional valve handle is in low position
(DHW position) (
¿JXUH
)
:
- Deactivate the DHW function,
- Wait a few moments for the handle to return to high
position.
2
- The directional valve handle is in high position
(heating position):
3
- Disconnect the RVS user interface layer (connector
X50) (
¿JXUH
)
.
4
- Connect the user interface layer to the LMS (X50).
- Initialising the interface takes a few minutes.
- Set the following parameters (Specialist level:
0DLQWHQDQFHVSHFLDORSHUDWLRQ
):
7143
= On
7145
= Enter the value required
100%
: operation at max
The burner runs at MAX rate.
- Let the boiler temperature reach 60°C.
- Carry out a combustion check.
- Check the CO
2
rate (see table below).
- If necessary, adjust the CO
2
rate by setting the gas
rate on the burner (screw item R1,
¿JXUH
).
- Adjust the parameter
7145
= Enter the value required
0%
: operation at min
The burner runs at MIN rate.
- Check the CO
2
rate (see table opposite).
- If necessary, adjust the pressure regulator setpoint
gently (screw item R2,
¿JXUH
).
- Check the settings at MAX rate. Modify if necessary.
"
When the settings are complete:
6HWWKHSDUDPHWHULQWKHLQLWLDOFRQ¿JXUDWLRQ
7143
= Off
5
-
Reconnect the user interface layer to the RVS
(X50). Initialising the interface takes a few minutes.
6
-
Reactivate the DHW function if necessary.
3.4.2 Heating installation with
1
XQGHUÀRRUKHDWLQJFLUFXLW
"
&ORVHWKHXQGHUÀRRUKHDWLQJFLUFXLWPL[HUYDOYH
PDQXDOO\
The energy created during this setting period
must be dissipated over the domestic circuit:
draw off some domestic hot water to lower the tank
temperature enough (< 35 °C).
1a
- The directional valve handle must be in low
position (DHW position) (
¿JXUH
)
. Follow the
procedure in
§
3.4.1
from N°
3
.
P
R1
+
-
B
R2
+
-
¿JXUH*DVYDOYH9*86
%
- Plug.
R1
*DVÀRZUDWHVHWWLQJRQWKHEXUQHU
R2
- Pressure regulator value setting.
P
- Gas inlet pressure (network).
Gas
Diaphragm
marker
0%
100%
CO
2
min
CO
2
max
G 20
20
8 to 9 %
8.5 to 9.5 %
G 25
no diaphragm
8 to 9 %
8.5 to 9.5 %
G 31
conical
9.5 to 10.5 %
10 to 11 %
¿JXUH
Rate of CO
2
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 44 -