![Atlantic alfea hybrid duo gas Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/atlantic/alfea-hybrid-duo-gas/alfea-hybrid-duo-gas_installation-and-commissioning-instructions_2999736022.webp)
L1
L1
L2
L2
90°
90°
¿JXUH
Connection possibilities (C13 and C33 type)
&W\SHSLSHFRQQHFWLRQ
&W\SHSLSHFRQQHFWLRQ
͞HOERZ
= 1 m of straight pipe.
͞HOERZ
= 0.5 m of straight pipe.
Existing evacuation pipe.
͞RIIVHW
= 0.5 m of straight pipe.
͞RIIVHW
= 0.3 m of straight pipe.
0D[LPXPVWUDLJKWOLQHOHQJWK
= 11 m (excluding terminal)
This length must be reduced by 1 m per 90° elbow and 0.5 m per 45° elbow.
Example of C13 type connection with 3 90° elbows: L1 + L2 + L3 + (3 x 1 m)
d
11 m.
Example of C33 type connection with 2 45° elbows: L1 + L2 + L3 + (2 x 0,5 m)
d
11 m .
Example of C33 type connection with Rénolux system:
͞HQWU\LQWRZDOOZLWKHOERZVDQGRIIVHWV//[P[P
d
11 m.
͞HQWU\LQWRZDOOZLWKRIIVHWV//[P
d
11 m.
RT
- Telescopic pipe.
T
- terminal (max 1 m).
Rénolux system
for adaptation to the existing evacuation pipe.
RT
RT
T
T
L
L1
L2
L3
45°
45°
Mini
16 et 24 kW
1577 mm
34 kW
1698 mm
28 et
3%
3%
L1
L3
L2
90°
90°
90°
3%
L1
L2
90°
3%
1899 mm
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 22 -