Specifications
Model name Aurea
5
8
10
16
Nominal heating performances
(outdoor temperature/ initial temperature)
Heat output
+7°C/+35°C - Under-floor heating
kW
5.00
8.00
10.00
16.00
-7°C / +35°C - Under-floor heating
kW
3.55
7.10
8.00
12.50
+7°C / +55°C - Radiator
kW
3.88
7.50
8.90
12.80
-7°C / +55°C - Radiator
kW
2.91
4.80
5.80
8.40
Power absorbed
+7°C / +35°C - Under-floor heating
kW
1.19
1.78
2.30
4.08
-7°C / +35°C - Under-floor heating
kW
1.38
2.93
3.32
5.68
+7°C / +55°C - Radiator
kW
1.56
2.67
3.25
5.10
-7°C / +55°C - Radiator
kW
1.78
2.95
3.35
5.53
Coefficient of performance (COP) (+7°C/+ 35°C)
4.20
4.50
4.35
3.92
Nominal cooling performances
(outdoor temperature/ initial temperature)
Cool output
+35°C / +18°C - Cooling floor system
kW
3.15
6.00
7.50
14.30
+35°C / +7°C - Fan convector
kW
2.40
4.50
5.60
10.70
Power absorbed
+35°C / +18°C - Cooling floor system
kW
0.75
1.75
2.35
4.15
+35°C / +7°C - Fan convector
kW
0.76
1.79
2.40
4.23
Cooling Efficiency (EER) (+35°C / + 18°C)
4.20
4.43
3.19
3.45
Electrical characteristics
Electrical voltage (50 Hz):
V
230
Maximum current of the appliance
A
10.9
15.2
17.5
25.3
Nominal current
A
5.6
8.0
10.2
17.8
Heating maximum electrical back-up current (option)
A
13.05 / 26.1
Heating electrical back-up power (option)
kW
6 kW
Outdoor unit maximum power absorbed
W
2500
3500
4025
5820
Rates as per EN14825
0.008
0.005
0.004
0.002
Hydraulic circuit
Maximum operating pressure
MPa (bar)
0.3 (3)
Minimum/maximum flow rate of the hydraulic circuit at
4°C<Δt<8°C (nominal conditions)
l/h
300 / 1200
600 / 2100
600 / 2100
900 / 3000
Miscellaneous
Weight of the outdoor unit
kg
49
72
72
117
Noise level at 5 m
1
(Outdoor unit)
dB (A)
47
(4)
47
(4)
47
(4)
47
(4)
Sound power level as per EN 12102-1 Annex A
2
(Outdoor unit)
dB (A)
60
62
65
66
Pipe diameters Flow/Return (Outdoor unit)
Inches
3/4
1
1
1 1/4
Weight of hydraulic unit (empty/full of water)
kg
40 / 62
Hydraulic module water capacity
l
22
Noise level at 1 m
1
(Hydraulic unit)
dB (A)
39
(4)
Sound power level as per EN 12102-1 Annex A
2
(Hydraulic unit)
dB (A)
46
Heating system operating limits
Min /max outdoor temperature
°C
-20 / +43
Initial max. heating water temperature °C Under-floor heating
°C
45
(4)
Max. water temperature for start of heating LT radiator
°C
55
Initial min. water temperature
°C
8
(4)
Refrigerant circuit
Factory charge of refrigerating fluid R410A
3
g
1050
1720
1720
2990
Maximum operating pressure
MPa (bar)
4.1 (41)
1
Sound pressure level at (x) m from the appliance, 1.5m from the ground, free field, directivity 2.
2
The acoustic power is a measurement made in the laboratory of the power of the noise emitted but contrary to the noise level, it does not correspond to the measurement of what is felt.
3
Refrigerant R410A in compliance with standard NF EN 378.1.
4
Temporary values.
Содержание AEYC-0639U-AT
Страница 13: ... ...
Страница 17: ... 17 1 A 1 A 2 3 S 4 5 6 B 6 B 7 fig 16 Remove the panel Aurea M Installation 1883 EN ...