![Atlantic AEYC-0639U-AT Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/atlantic/aeyc-0639u-at/aeyc-0639u-at_installation-manual_2999728024.webp)
- 24 -
▼ Access to the connection terminals
-Remove the front panel (2 screws) (
fig. 16, page 17
).
-
Open the power control box.
-Make the connections according to the diagram
fig. 22, page 24
.
Do not fit the sensor wires and the power supply wires
in parallel in order to avoid interferences due to the
voltage surges in the power supply.
Ensure that all of the electrical cables are housed in the
spaces provided.
▼
Interconnection between the heat pump
and the hydraulic unit
Comply with the correspondence between the markings
on the hydraulic unit's terminals and those on the heat
pump when connecting the interconnection cables.
An incorrect connection can cause the destruction of
one of the units.
►
Electrical connections on the hydraulic unit side
1 2 3
4
5
6
L N
L N 1
POWER
2 3
Outdoor unit
Hydraulic unit
Single phase 230 V
electric power supply
to outdoor element
contact *
red
blue
brown
green/yellow
Interconnection between
the heat pump
and the hydraulic unit
fig. 22 -
Connection to the terminal blocks
Aurea M / Installation / 1883 - EN
Содержание AEYC-0639U-AT
Страница 13: ... ...
Страница 17: ... 17 1 A 1 A 2 3 S 4 5 6 B 6 B 7 fig 16 Remove the panel Aurea M Installation 1883 EN ...