11
i
nstallation
SANITAIRE
®
Model RSM2680 Room Air Sanitizer is completely mobile and requires no professional installation. It is equipped
with 4 locking, swivel casters, and can be moved to any location. Plug the fixture into an appropriate power source, matching the
fixture’s requirements. The fixture is now ready for use.
d
imensional
d
ata
Figure 13 – Dimensional Data
All specifications, dimensional data, etc. are approximate and subject to change without notice.
s
etuP
i
nstruCtions
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY
EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
Always disconnect power to the fixture before performing any service or maintenance
.
The
SANITAIRE
®
Model RSM2680 is mobile and does not require professional installation.
1.
Place fixture in selected location.
2. Install
STER-L-RAY
®
lamps following the steps in the
“Lamp Installation”
section of this manual on
Pages 8–9
.
3. The
SANITAIRE
®
Model RSM2680, ships with the (4) intake filters installed within the lower intake grills. See
“Filter
Replacement”
on
Page 10
for further details on these filters.
4.
Plug power cord into the electrical outlet with the matching power requirement listed on the unit’s rear specification label.
5. Verify
STER-L-RAY
®
lamp operation by turning the power key to the right
(Figure 4 on Page 8)
. All lamp LEDs should glow
green on the Front Monitoring Panel
(See Figure 3 on Page 7)
. If any of the lamp displays glow
RED
rather than
GREEN
,
which indicates that they are not operating properly, go to the
“Troubleshooting”
section of this manual on
Page 14
.
Avoid exposure to direct or reflected germicidal ultraviolet rays.
Germicidal ultraviolet rays are harmful to the eyes and skin.