Atlantic Ultraviolet SANITAIRE RSM2680 Скачать руководство пользователя страница 6

6

P

rinCiPle

 

of

 o

Peration

The 

SANITAIRE

®

 design has been carefully conceived to provide germicidal ultraviolet exposure for air disinfection. The 

dosage, as it applies to ultraviolet disinfection, is a function of time, and the intensity, of ultraviolet radiation, to which the air 

is exposed. The exposure time, in seconds, is the total time it takes the air to move through the ultraviolet field, produced by the 

germicidal lamps. Exposure time is related to the airflow rate, the higher the airflow, the lower the exposure time or the lower the 

airflow, the higher the exposure time. The operation of the 

SANITAIRE

®

 Germicidal Ultraviolet Room Air Sanitizer is as follows:

1. 

Air from the room is drawn into the fixture through the four intake grills in the lower half of the unit’s body and pulled thru 

the pleated filters behind each of these grills.

2.  The air is forced upwards into the exposure chamber, where it is irradiated by the eight germicidal ultraviolet lamps.
3.  The treated air exits the top of the unit, through the louvered- exhaust panel and reintroduced to the room. 

(See Figure 2)

.

 It is the user’s responsibility to determine and validate the suitability of the equipment for use in system 

or process. No warranty or representation is made by the manufacturer with respect to suitability or performance of this 

equipment or to the results that may be expected from its use.

 Indoor Use Only – The equipment must be sheltered from exposure to the elements and extremes in 

temperature. Temperature range: 40°F to 95°F. The user should periodically inspect, clean as necessary and confirm the 

presence and good legibility of the Product safety labels. Contact the factory for replacement labels in the event that any of 

the labeling is missing or illegible.

 The UV Treatment Results achieved are subject to variations in application conditions, it is recommended 

that culture tests be performed to confirm desired outcomes.

l

imitation

 

of

 u

se

•  Overexposure to germicidal ultraviolet rays will 

result in the irritation of the eyes and reddening 

of the skin. For that reason, it is of the utmost 

importance that your ultraviolet application be 

carefully planned and implemented so as to 

avoid exposure of people and other living things 

to direct or reflected ultraviolet rays.

•  The American Conference of Governmental 

Industrial Hygienists (

ACGIH

) has established 

that the ultraviolet radiant exposure incident for 

unprotected eyes or skin should not exceed 0.2 

microwatts per square centimeter (

µW/cm2

at 254 nanometers (

nm

) for an eight (8) hour 

period. (

“2004 TLVs

®

 and BEIs

®

)

Figure 2 – 

SANITAIRE

®

 RSM2680 Germicidal 

UV Room Air Sanitizer Operation

Содержание SANITAIRE RSM2680

Страница 1: ...ice Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Ultraviolet com BuyUltraviolet com Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions ...

Страница 2: ...ltraviolet Corporation and are believed to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 CAUTION 3 SAFETY LABELING 4 PRODUCT FEATURES 5 Construction 5 Principle of Operation 6 Limitation of Use 6 UNPACKIN...

Страница 3: ...other moving parts that can cause injuries 14 Utility power supplied to the unit MUST match power requirements listed on the unit label 15 Always disconnect power to the unit before performing any service or maintenance 16 Read and follow all notices and warnings on the unit 17 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product...

Страница 4: ...C Radiation 70 0052A On both Access Doors Warning UV C Radiation 70 0052A x4 1 per side Hg Lamp Contains Mercury 70 0011 Also 3x inside unit by lamp bases Disconnect Turn Off Unit Before Opening Access Door 70 0121 x2 Front and Back Danger Hazardous Voltage 70 0053 See additional locations below Danger Hazardous Voltage 70 0053 ...

Страница 5: ... limits ultraviolet radiation from passing into the room helps to protect the room s occupants from ultraviolet exposure Stainless Steel Construction All stainless steel frame and access panels doors constructed of type 304 Stainless steel construction provides strength durability and lasting value Keyed Power Switch Power operation controlled by key access to ensure fixture is controlled by autho...

Страница 6: ...anty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use Indoor Use Only The equipment must be sheltered from exposure to the elements and extremes in temperature Temperature range 40 F to 95 F The user should periodically inspect clean as necessary and confirm the presence and good legibilit...

Страница 7: ...zer from its shipping crate Atlantic Ultraviolet Corporation takes all possible precautions when packaging this fixture to prevent damage Carefully inspect the sanitizer power cord and plug for damage Report all damage immediately Do not assemble or operate if there is any damage visible or suspected STER L RAY Germicidal lamps are packed separately to ensure maximum protection for the lamps Keep ...

Страница 8: ... down the reset button for about five seconds until the timer lights flash and the green light comes on Figure 5 SANITAIRE RSM2680 Lamp and Filter Reset Buttons INSTALLATION Lamp Installation IN ORDER TO PERFORM THIS TASK BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT SAFETY GLASSES OR A FACE SHIELD AS WELLAS GLOVES Always disconnect power to the fixture before performing any service or maintenanc...

Страница 9: ... lamp so that its pin configuration matches the lampholder carefully push the lamp into the connector See Figure 8 6 Once the STER L RAY lamp is securely seated into the connector carefully push it into the end support See Figure 9 7 Repeat until all STER L RAY lamps have been installed into the unit Close access doors and restore power to the unit 8 Verify unit operation by viewing the Monitoring...

Страница 10: ...ure is recommended for use in large conference rooms auditoriums or any large area which may or may not contain occupants For maximum efficiency the SANITAIRE should be located as centrally as possible Access to the room does not need to be controlled while the fixture is operating The louvered exhaust panel on the top of the SANITAIRE Germicidal Ultraviolet Room Air Sanitizer limits ultraviolet r...

Страница 11: ... professional installation 1 Place fixture in selected location 2 Install STER L RAY lamps following the steps in the Lamp Installation section of this manual on Pages 8 9 3 The SANITAIRE Model RSM2680 ships with the 4 intake filters installed within the lower intake grills See Filter Replacement on Page 10 for further details on these filters 4 Plug power cord into the electrical outlet with the ...

Страница 12: ...lowing GREEN to YELLOW or RED Flashing 1 Disconnect power to the fixture and unplug from the electrical outlet 2 Unlock and open the front and rear doors of the SANITAIRE to gain access to the interior of the unit 3 Remove each STER L RAY lamp starting with the closest by holding the lamp by the base and carefully pulling the lamp out of the upper lamp clip Once lamp base is free from upper lamp c...

Страница 13: ...ndling broken ultraviolet lamps In the event of breakage DO NOT use a household vacuum cleaner to pick up quartz fragments Sweep up debris into a plastic bag and dispose of properly Disposal of Mercury Added Lamps Germicidal ultraviolet lamps like standard fluorescent lamps contain small amounts of mercury Mercury added lamps should not be placed in the trash Dispose of properly For further inform...

Страница 14: ... steps above do not fix problem replace ballast corresponding to non functioning lamp All STER L RAY Germicidal Lamps not operating STER L RAY Lamps not installed Install lamps Interlock switch open Confirm access cover is on and latched Interlock switch faulty Replace interlock switch If the above measures fail to correct the problem s contact our UV Application Specialists Contact options can be...

Страница 15: ...8 10 0138 3 Promate Filter MERV 7 4 40 0119 4 Blower Belt Driven Blower with Motor 1 40 1485 5 Steadfast Lamp Socket 8 35 1104A 6 Interlock Switch 2 35 0128 7 Blower Relay 1 35 0007 8 Key Power Switch 1 35 1422 9 Line Cord 120v 1 35 1483 10 Reset Push Button Switch 2 35 3255 Other replacement parts are available Consult the Factory for specific requirements MAINTENANCE NOTES ...

Страница 16: ...ter receipt and shall notify us at our main office in writing of claims including claims of breach of warranty within thirty 30 days after the Buyer discovers or should have discovered the facts upon which the claim is based Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim The provisions of the above warranty are our sole ob...

Отзывы: