background image

13

i

ntaKe

 f

ilter

These filters require regular replacement and should be replaced when the Filter Replacement Indicators, located on the 

front monitor display changes from glowing GREEN to YELLOW or RED (Flashing).

•  The 

SANITAIRE

®

 Germicidal Ultraviolet Room Air Sanitizers are fitted with (4) Synthetic Pleated (MERV 7) Filters.

•  Disconnect power to the 

SANITAIRE

®

.

• 

Turn the two white plastic latches on each of the top corners of the lower filter grill and allow the grill to pivot out to expose 

the filter behind the grill. Once the filter is exposed, slide it 

from its location. 

(See “Filter Replacement” on Page 10)

• 

Once the filter is removed, use a vacuum to remove any 

trapped dust or dirt in and along the filter frame.

 

  

Be careful not to damage the protective 

mesh located in the back of the filter frame. Contact factory 

if this mesh is ever damaged or appears to need replacement 

(See Figure 14)

.

• 

Position the replacement filter so that the arrows on the 

filter showing the flow direction face inwards to the unit 

and slide the filter into the frame. 

(See Figure 12 in “Filter 

Replacement” Section on Page 10)

• 

Once the filter is in place, pivot the filter grill back into 

place and rotate the two white plastic latches securing the 

filter in place.

B

reaKage

Broken Quartz is SHARP. 

Wear protective gloves when handling broken ultraviolet lamps. In the event of breakage, 

DO NOT

 use a household vacuum cleaner to pick up quartz fragments. Sweep up debris into 

a plastic bag and dispose of properly

.

d

isPosal

 

of

 m

erCury

 a

dded

 l

amPs

Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added 

lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and 

recycling of lamps containing mercury, along with Federal and State requirements visit LampRecycle.org. For more 

information on 

STER-L-RAY

®

 

Germicidal Ultraviolet Lamps, visit Ultraviolet.com or BuyUltraviolet.com.

OPTIONAL ACCESSORIES 

1. 

Zenith

 

Germicidal Ultraviolet Detector (30-1015):

 A sensitive, hand-held, self-contained battery operated ultraviolet 

meter that can be used for:

•  Monitoring UV-C Germicidal Lamp Intensity & Aging

•  Measuring UV-C Germicidal Fixture Leakage

2. 

Promate

TM

 

Safety Glasses (00-1299): 

Safety eyewear 

MUST

 be used as general-purpose safety protection and for 

additional shielding from ultraviolet rays.

3. 

Promate

TM

 

Face Shield (00-0126): 

Lightweight visor with adjustable headgear provides eye and face protection from 

germicidal ultraviolet rays.

For more information and purchasing contact our offices, weekdays between 8:30 am and 5:00 pm Eastern time, at:

 

Atlantic Ultraviolet Corporation

®

, 375 Marcus Boulevard, Hauppauge, New York, 11788  

Tel: (631) 273-0500 • Fax: (631) 273-0771 • Email: [email protected] • Website: Ultraviolet.com – BuyUltraviolet.com

Figure 14

Содержание SANITAIRE RSM2680

Страница 1: ...ice Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Ultraviolet com BuyUltraviolet com Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions ...

Страница 2: ...ltraviolet Corporation and are believed to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 CAUTION 3 SAFETY LABELING 4 PRODUCT FEATURES 5 Construction 5 Principle of Operation 6 Limitation of Use 6 UNPACKIN...

Страница 3: ...other moving parts that can cause injuries 14 Utility power supplied to the unit MUST match power requirements listed on the unit label 15 Always disconnect power to the unit before performing any service or maintenance 16 Read and follow all notices and warnings on the unit 17 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product...

Страница 4: ...C Radiation 70 0052A On both Access Doors Warning UV C Radiation 70 0052A x4 1 per side Hg Lamp Contains Mercury 70 0011 Also 3x inside unit by lamp bases Disconnect Turn Off Unit Before Opening Access Door 70 0121 x2 Front and Back Danger Hazardous Voltage 70 0053 See additional locations below Danger Hazardous Voltage 70 0053 ...

Страница 5: ... limits ultraviolet radiation from passing into the room helps to protect the room s occupants from ultraviolet exposure Stainless Steel Construction All stainless steel frame and access panels doors constructed of type 304 Stainless steel construction provides strength durability and lasting value Keyed Power Switch Power operation controlled by key access to ensure fixture is controlled by autho...

Страница 6: ...anty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use Indoor Use Only The equipment must be sheltered from exposure to the elements and extremes in temperature Temperature range 40 F to 95 F The user should periodically inspect clean as necessary and confirm the presence and good legibilit...

Страница 7: ...zer from its shipping crate Atlantic Ultraviolet Corporation takes all possible precautions when packaging this fixture to prevent damage Carefully inspect the sanitizer power cord and plug for damage Report all damage immediately Do not assemble or operate if there is any damage visible or suspected STER L RAY Germicidal lamps are packed separately to ensure maximum protection for the lamps Keep ...

Страница 8: ... down the reset button for about five seconds until the timer lights flash and the green light comes on Figure 5 SANITAIRE RSM2680 Lamp and Filter Reset Buttons INSTALLATION Lamp Installation IN ORDER TO PERFORM THIS TASK BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT SAFETY GLASSES OR A FACE SHIELD AS WELLAS GLOVES Always disconnect power to the fixture before performing any service or maintenanc...

Страница 9: ... lamp so that its pin configuration matches the lampholder carefully push the lamp into the connector See Figure 8 6 Once the STER L RAY lamp is securely seated into the connector carefully push it into the end support See Figure 9 7 Repeat until all STER L RAY lamps have been installed into the unit Close access doors and restore power to the unit 8 Verify unit operation by viewing the Monitoring...

Страница 10: ...ure is recommended for use in large conference rooms auditoriums or any large area which may or may not contain occupants For maximum efficiency the SANITAIRE should be located as centrally as possible Access to the room does not need to be controlled while the fixture is operating The louvered exhaust panel on the top of the SANITAIRE Germicidal Ultraviolet Room Air Sanitizer limits ultraviolet r...

Страница 11: ... professional installation 1 Place fixture in selected location 2 Install STER L RAY lamps following the steps in the Lamp Installation section of this manual on Pages 8 9 3 The SANITAIRE Model RSM2680 ships with the 4 intake filters installed within the lower intake grills See Filter Replacement on Page 10 for further details on these filters 4 Plug power cord into the electrical outlet with the ...

Страница 12: ...lowing GREEN to YELLOW or RED Flashing 1 Disconnect power to the fixture and unplug from the electrical outlet 2 Unlock and open the front and rear doors of the SANITAIRE to gain access to the interior of the unit 3 Remove each STER L RAY lamp starting with the closest by holding the lamp by the base and carefully pulling the lamp out of the upper lamp clip Once lamp base is free from upper lamp c...

Страница 13: ...ndling broken ultraviolet lamps In the event of breakage DO NOT use a household vacuum cleaner to pick up quartz fragments Sweep up debris into a plastic bag and dispose of properly Disposal of Mercury Added Lamps Germicidal ultraviolet lamps like standard fluorescent lamps contain small amounts of mercury Mercury added lamps should not be placed in the trash Dispose of properly For further inform...

Страница 14: ... steps above do not fix problem replace ballast corresponding to non functioning lamp All STER L RAY Germicidal Lamps not operating STER L RAY Lamps not installed Install lamps Interlock switch open Confirm access cover is on and latched Interlock switch faulty Replace interlock switch If the above measures fail to correct the problem s contact our UV Application Specialists Contact options can be...

Страница 15: ...8 10 0138 3 Promate Filter MERV 7 4 40 0119 4 Blower Belt Driven Blower with Motor 1 40 1485 5 Steadfast Lamp Socket 8 35 1104A 6 Interlock Switch 2 35 0128 7 Blower Relay 1 35 0007 8 Key Power Switch 1 35 1422 9 Line Cord 120v 1 35 1483 10 Reset Push Button Switch 2 35 3255 Other replacement parts are available Consult the Factory for specific requirements MAINTENANCE NOTES ...

Страница 16: ...ter receipt and shall notify us at our main office in writing of claims including claims of breach of warranty within thirty 30 days after the Buyer discovers or should have discovered the facts upon which the claim is based Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim The provisions of the above warranty are our sole ob...

Отзывы: