USER ASSISTANCE

Atlantic Ultraviolet Corporation

®

 

makes every effort to ensure that the 

SANITAIRE

®

 Germicidal Ultraviolet 

Room Air Sanitizer Model RSM2680 

is a product of superior quality and 

workmanship. This manual describes 

the installation, operation and 

maintenance of the 

SANITAIRE

®

 

Germicidal Ultraviolet Room Air 

Sanitizer Model RSM2680.

Please read and become familiar with 

the contents of this manual before 

installing or using this unit. If after 

reading the manual you still have 

questions, or concerns, regarding the 

installation or use of this unit, contact 

our offices, weekdays between 8:30 am 

and 5:00 pm Eastern Time, at:

Atlantic Ultraviolet Corporation

®

375 Marcus Boulevard

Hauppauge, New York, 11788
Tel: (631) 273-0500

Fax: (631) 273-0771
Email: [email protected]

Website: Ultraviolet.com

 BuyUltraviolet.com

WARRANTY & PRODUCT REGISTRATION 

We warrant this product to the original owner to be free from defects in material and workmanship when installed in 

accordance with Atlantic Ultraviolet Corporation

®

 specifications for a period of time as follows:

UV Water Purifier Chambers

 – Type 316 stainless steel chambers will have a Twelve (12) year Limited Warranty on the stainless 

steel chamber, from the date of original purchase while the Type 304 stainless steel chambers will have a Six (6) year Limited 

Warranty on the stainless steel chamber.

UV Air Disinfection Housing

 – Three (3) year Limited Warranty on the metal housing, from the date of original purchase.

Ballasts

 – Three (3) year Limited Warranty, from the date of original purchase.

UV Lamps, Monitoring Devices, Optional Accessories, and Other Parts

 – One (1) year Limited Warranty from the date  

of original purchase.
Within the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid and which 

are determined by us to be defective. This warranty will not apply to any product, which has been subjected to misuse, negligence or 

accident; or misapplied; or modified; or repaired by unauthorized person; or improperly installed. Warranty will be null and void if 

any of the product’s original labels are removed. This Limited warranty excludes the cost of labor.

The Buyer shall inspect the product promptly after receipt and shall notify us at our main office in writing of claims, including claims 

of breach of warranty, within thirty (30) days after the Buyer discovers or should have discovered the facts upon which the claim is 

based. Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim.
The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties, expressed or implied, 

including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described 

herein. We further disclaim any responsibility whatsoever to the customer, or to any person for injury to person, damage to, or loss 

of property or value caused by any product which has been subjected to misuse, negligence, accident; or modified or repaired by 

unauthorized persons; or improperly installed.
Under no circumstances shall the Company be liable for any incidental, consequential or special damages; losses or expenses arising 

from the contract for this product, or in connection with the use of, or inability to use, our product for any purpose whatsoever.
Be sure to register your product and validate purchase within 30 days –registration is simple and will take less than 2 minutes to do. 

NOTE

 – failure to register your purchase may jeopardize warranty.

Go to Ultraviolet.com and scroll down to the bottom of the page, under “Trust” click the “Warranty Registration Form”, complete and 

click “Submit”. Or click on “Warranty Registration PDF” to download the warranty registration card as a PDF, complete and mail to 

us at 375 Marcus Boulevard, Hauppauge, NY 11788, or simply fax to (631) 273-0771. If you prefer to register by phone, please call 

(631) 273-0500 and our customer service staff will be glad to assist you.
For your convenience, record the following information below. The model and serial number can be found on a label located 

on the 

SANITAIRE

®

 Germicidal Ultraviolet Room Air Sanitizer Model RSM2680. Keep this manual, along with proof of purchase, 

handy when contacting our offices.

Purchased From:

Date:

Model:

Serial No.:

P

atent

 n

otiCe

No attempt has been made to determine the patent status of applications illustrated or described in this publication. Inclusion in  

this publication of any design or method of use, which may be patented, is not to be construed as promoting or sanctioning 

unauthorized use.

Содержание SANITAIRE RSM2680

Страница 1: ...ice Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Ultraviolet com BuyUltraviolet com Extensive Product Information Available at Ultraviolet com BuyUltraviolet com Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions ...

Страница 2: ...ltraviolet Corporation and are believed to be correct However no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein Specifications and information are subject to change without notice SAFETY WARNINGS 3 SAFETY INSTRUCTIONS 3 CAUTION 3 SAFETY LABELING 4 PRODUCT FEATURES 5 Construction 5 Principle of Operation 6 Limitation of Use 6 UNPACKIN...

Страница 3: ...other moving parts that can cause injuries 14 Utility power supplied to the unit MUST match power requirements listed on the unit label 15 Always disconnect power to the unit before performing any service or maintenance 16 Read and follow all notices and warnings on the unit 17 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product...

Страница 4: ...C Radiation 70 0052A On both Access Doors Warning UV C Radiation 70 0052A x4 1 per side Hg Lamp Contains Mercury 70 0011 Also 3x inside unit by lamp bases Disconnect Turn Off Unit Before Opening Access Door 70 0121 x2 Front and Back Danger Hazardous Voltage 70 0053 See additional locations below Danger Hazardous Voltage 70 0053 ...

Страница 5: ... limits ultraviolet radiation from passing into the room helps to protect the room s occupants from ultraviolet exposure Stainless Steel Construction All stainless steel frame and access panels doors constructed of type 304 Stainless steel construction provides strength durability and lasting value Keyed Power Switch Power operation controlled by key access to ensure fixture is controlled by autho...

Страница 6: ...anty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use Indoor Use Only The equipment must be sheltered from exposure to the elements and extremes in temperature Temperature range 40 F to 95 F The user should periodically inspect clean as necessary and confirm the presence and good legibilit...

Страница 7: ...zer from its shipping crate Atlantic Ultraviolet Corporation takes all possible precautions when packaging this fixture to prevent damage Carefully inspect the sanitizer power cord and plug for damage Report all damage immediately Do not assemble or operate if there is any damage visible or suspected STER L RAY Germicidal lamps are packed separately to ensure maximum protection for the lamps Keep ...

Страница 8: ... down the reset button for about five seconds until the timer lights flash and the green light comes on Figure 5 SANITAIRE RSM2680 Lamp and Filter Reset Buttons INSTALLATION Lamp Installation IN ORDER TO PERFORM THIS TASK BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT SAFETY GLASSES OR A FACE SHIELD AS WELLAS GLOVES Always disconnect power to the fixture before performing any service or maintenanc...

Страница 9: ... lamp so that its pin configuration matches the lampholder carefully push the lamp into the connector See Figure 8 6 Once the STER L RAY lamp is securely seated into the connector carefully push it into the end support See Figure 9 7 Repeat until all STER L RAY lamps have been installed into the unit Close access doors and restore power to the unit 8 Verify unit operation by viewing the Monitoring...

Страница 10: ...ure is recommended for use in large conference rooms auditoriums or any large area which may or may not contain occupants For maximum efficiency the SANITAIRE should be located as centrally as possible Access to the room does not need to be controlled while the fixture is operating The louvered exhaust panel on the top of the SANITAIRE Germicidal Ultraviolet Room Air Sanitizer limits ultraviolet r...

Страница 11: ... professional installation 1 Place fixture in selected location 2 Install STER L RAY lamps following the steps in the Lamp Installation section of this manual on Pages 8 9 3 The SANITAIRE Model RSM2680 ships with the 4 intake filters installed within the lower intake grills See Filter Replacement on Page 10 for further details on these filters 4 Plug power cord into the electrical outlet with the ...

Страница 12: ...lowing GREEN to YELLOW or RED Flashing 1 Disconnect power to the fixture and unplug from the electrical outlet 2 Unlock and open the front and rear doors of the SANITAIRE to gain access to the interior of the unit 3 Remove each STER L RAY lamp starting with the closest by holding the lamp by the base and carefully pulling the lamp out of the upper lamp clip Once lamp base is free from upper lamp c...

Страница 13: ...ndling broken ultraviolet lamps In the event of breakage DO NOT use a household vacuum cleaner to pick up quartz fragments Sweep up debris into a plastic bag and dispose of properly Disposal of Mercury Added Lamps Germicidal ultraviolet lamps like standard fluorescent lamps contain small amounts of mercury Mercury added lamps should not be placed in the trash Dispose of properly For further inform...

Страница 14: ... steps above do not fix problem replace ballast corresponding to non functioning lamp All STER L RAY Germicidal Lamps not operating STER L RAY Lamps not installed Install lamps Interlock switch open Confirm access cover is on and latched Interlock switch faulty Replace interlock switch If the above measures fail to correct the problem s contact our UV Application Specialists Contact options can be...

Страница 15: ...8 10 0138 3 Promate Filter MERV 7 4 40 0119 4 Blower Belt Driven Blower with Motor 1 40 1485 5 Steadfast Lamp Socket 8 35 1104A 6 Interlock Switch 2 35 0128 7 Blower Relay 1 35 0007 8 Key Power Switch 1 35 1422 9 Line Cord 120v 1 35 1483 10 Reset Push Button Switch 2 35 3255 Other replacement parts are available Consult the Factory for specific requirements MAINTENANCE NOTES ...

Страница 16: ...ter receipt and shall notify us at our main office in writing of claims including claims of breach of warranty within thirty 30 days after the Buyer discovers or should have discovered the facts upon which the claim is based Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim The provisions of the above warranty are our sole ob...

Отзывы: