Chapter one: System overview

 

1.1 System introduction

 

          The 

ATL -9000 

fire alarm control panel (linkage type) (fire alarm control panel) is a new

 

generation product 

launched by 

ATL

, In order to adapt to the needs of engineering

 

design, the fire alarm control panel is designed with 

a linkage control function that enables it to

 

be flexibly used with other related products from 

ATL 

to form a fire 

alarm and

 

linkage integrated control system. It is particularly suitable for applications in large and

 

medium-sized fire 

alarm and linkage integrated control systems. The fire alarm and linkage control system is extensively applied in 
high-grade office buildings, big

 

residence communities, department stores, gymnasiums, exhibition halls, libraries, 

factory buildings,

 

supermarkets, hotels and other large and medium-sized fire protection projects

.

 

1.2 System characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

It adopts new generation high-speed microprocessor technology that has a data processing

 

speed and a data storage capacity 100 times and 1000 times higher than that of conventional

 

technology respectively.

 

It has a 7.4

″16-grey-scale LCD Chinese-supporting display and with a display resolution of

 

640×480.

 

Its operating interfaces simulate the menus and interfaces of Windows and therefore ensure

 

operation habits similar to that of computers and is easy to learn.

 

It uses a flexibly and conveniently controllable standard PS/2 computer keyboard and mouse

 

as on-site programming devices.

 

It provides a Chinese Pinyin input method and a Chinese section-position code input method

 

and can therefore realize Chinese input freely and easily.

 

It can copy or restore both setting files and historical files through a CF intelligent storage

 

card (optional), making system maintenance convenient.

 

It adopts a non-polarity two-bus intelligent alarm linkage mode and has a total of 324

 

intelligent detectors or modules for a single circuit. The addresses of the intelligent detectors

 

or modules may be hashed with No.1 to No.324.

 

It is equipped with multiple high-speed CAN-bus interfaces, ensuring quick and reliable data

 

transmission.

 

It has super high single-machine capacity (maximum single-machine capacity:

 

40×2×324=25,920 alarm points).

 

It supports the networking of 20 

ATL-9000 

fire alarm control panels. It has

 

a maximum capacity of 518,400 alarm points (20×25,920) after networking.

 

It can be connected with a multi-line linkage control unit and has a maximum capacity of

 

4,000 points for a standalone linkage control unit.

 

It can store the historical information of system operation, including 1,000 pieces of historical

 

fire alarm information, historical request information, historical feedback information,

 

historical fault information and historical operation information respectively.

 

Users can customize the equipment type, making system integration convenient.

 

It introduces the concept of a virtual interface board to realize the linkage operations of

 

general semantics, thus realizing the most complicated system linkage relations easily.

 

It has manual single-point start and stop functions for modules, making on-site debugging

 

and tests convenient.

 

It has a single-point test function for detectors or modules, making the operating conditions

 

and test data of detectors intuitive.

 

It has a standard special mini printer, enabling it to print various operating conditions in a

 

real-time way.

 

It can be accessed to a zone display panel, a building display panel or a floor display panel to

 

send the information displayed on it to locations like corridors.

 

It can be connected with the ATL-982 graphical display device (optional, ATL-982 for

 

short) in the fire control room to display the specific locations of fires and faults intuitively.

 

It executes administration by different levels for users of multiple levels and grants the users

 

1

 

Содержание ATL-9000 Series

Страница 1: ...m Control Panel Linkage Type ATL 9000 SERIES ATL 9000 2 ATL 9000 4 ATL 9000 6 Angel Technologies Hongkong Ltd Add 3 F South Gate Chuangsheng Building XiIi Twon Yangguang Industrial Zone Nanshan Distri...

Страница 2: ...rations of the system into Chinese The system can realize comprehensive on site programming and solve complicated linkage relation settings The system simulates the operating interfaces of Windows and...

Страница 3: ...arm linkage mode and has a total of 324 intelligent detectors or modules for a single circuit The addresses of the intelligent detectors or modules may be hashed with No 1 to No 324 It is equipped wit...

Страница 4: ...rities making system administration convenient It can realize local or remote software upgrades thus enabling it to operate stably and reliably Executive standards Fire Alarm Control Units GB4717 2005...

Страница 5: ...panel Fire display panel 1 L 1 L PH O NE A LA R M Powersupply PRE SS HER E 1 3 System schematic diagram CFT QGL 9000 CFT QGL 9000 Intelligent 80 L smoke detector 80 L Intelligent heat detector Intell...

Страница 6: ...terface board has two circuits Each of the two circuits can drive 324 intelligent detectors or modules Fire detector The system can be accessed to multiple intelligent smoke heat or composite detector...

Страница 7: ...chnical parameters of the products of the system 1 5 1 Power supplies Main power supply AC 220V 20 50Hz or DC24V Emergency power supply Maintenance free DC24V battery its capacity depends on the syste...

Страница 8: ...mensions of system engineering 2 1 Outline drawing and dimensional drawing of the product Appearance and dimensions of CFT QTL 9000 Main control unit Manual control unit Linkage unit Blank cover Print...

Страница 9: ...Appearance and dimensions of CFT QGL 9000 Host cover Manual control unit Linkage unit Keyboard mouse Printer Blank cover Fig 2 2 Cabinet Dimensions 7...

Страница 10: ...Lashing eye Scale3 1 Lashing eye Scale3 1 Inlet wire Fig 2 3 CFT QBL 9000 diagrammatic sketch 8...

Страница 11: ...key and so on After checking the above do necessary inspections for the appearance of the fire alarm control panel If any non conformities are discovered in the check or inspections call our salesper...

Страница 12: ...he insulation resistances between the buses of different circuits and that between the buses and ground as well as the loads of the circuits The insulation resistances should be larger than 20M and th...

Страница 13: ...ANCEALARM OPERATIONDELAY POWER FAULT HO RN STROBEFAULT C MN AOM U IC TION SURVEILLANCEFAULT SYST TESTEM AUTO MANUAL K OREYB A D ISO TIOLA N GN AE ER LL KGIN A E R ETES SO N ERUDLIN A EKG SELE TC SSE T...

Страница 14: ...en a fire alarm triggers a linkage and it will go out when all the linkage delays have ended and all the linkages have been established It will be lit when a power supply alarm of the fire alarm contr...

Страница 15: ...power failure and is then powered on again the integration control state before the power failure will be restored User s Tip Integration refers to the integration control except for the sounder Sound...

Страница 16: ...larms for the alarm information of the bus equipment The fault information of the interface boards the power supplies the printer the display panels and the communication of the fire alarm control pan...

Страница 17: ...re alarm request feedback area fault area CONFIRM Confirm the activity area fire alarm request feedback area fault area Downward rolling Input the area area password Move the cursor upward SELECT Sele...

Страница 18: ...upy 30 continuous bus module addresses The quantity of the manual control panels that may be accessed to a fire alarm control panel depends on the quantity of the interface boards There are 11 initial...

Страница 19: ...US TNE TR B U STNE TRB U SENT TRB US TNE TR B U STNE TRB U STNE Fig 7 1 Multi line Linkage Control Unit The quantity of the multi line control points that may be accessed depends on the quantity of th...

Страница 20: ...nd d Check whether there are linkage setting data in the linkage setup or not or whether the Register option in the linkage data is selected or not After the system reports a fire alarm linkage may be...

Страница 21: ...rol panel nor slave fire alarm control panel s in the networked system Only after another fire alarm control panel has its number registered can the alarm information of the current fire alarm control...

Страница 22: ...ely The other two yellow lights are respectively the short or open circuit lights for the No 1 circuit and the No 2 circuit There are two circumstances of open circuit Complete open circuit or partial...

Страница 23: ...0 Positive pressure fan 11 Blow valve 12 Air blower 13 Fire damper 14 Fire door 15 Deluge valve 17 Spray pump 18 Stabilizing pump 19 Fire pump 20 Foam pump 21 Water curtain pump 22 Municipal electrici...

Страница 24: ...1 L2 J k1 J k 2 S p 1 S p 2 J k1 J k 2 S p 1 S p 2 J k1 J k 2 S p 1 S p 2 9000 series host Bro a d ca stin g m o d u le Bro a d ca stin g m o d u le Bro a d ca stin g m o d u le 485 Bus Louds peak er...

Страница 25: ...y 485 Bus Fault input 485 bus hub 1 2 3 4 5 6 Remot e B ackup Self control power inspection Publicf ailure Circ uit 1 Circ uit 2 DC2 4 Output Input Output 1 2 3 4 5 6 Broadc as ting c ontroller Broadc...

Страница 26: ...A N interface Constant vol tage i nput 1 Constant vol tage output 1 Constant vol tage i nput 2 Constant voltage output 2 Amplifier failure input 1 2 RS485 A B Line C output GND 24 E CAN CAN HL C asca...