RS-232 Commands
Task
RS-232 Command
Description
Switch Port
Switch output port(s)
on
sw o<output_number>
on
Switch on one or all output ports. For
example, to turn output port 02, type
sw o02 on
output_number: 01-10, * (all output
ports)
Switch output port(s)
off
sw o<output_number>
off
Switch off one or all output ports. For
example, to turn off all output ports,
type:
sw o* off
output_number: 01-10, * (all output
ports)
EDID
Implement the
display’s EDID
edid portyy
Implement the EDID of the display
connected to Port yy, and pass it to
the video source.
yy: 01-10
Implement auto EDID edid auto
Implement the EDID of all connected
displays. The VS0110HA uses the
best resolution for all displays.
Implement ATEN
default EDID
edid defaultyy
Implements the specified ATEN
default EDID configuration.
yy: 00-09, default is 00 (see
Baud Rate Setting
Set up the baud rate
baud
<baud_rate_value>
For example, to set the baud rate to
9600, type:
baud 9600
baud_rate_value: 9600, 19200
(default), 38400, 115200
Read Information
Read (display) the
VS0110HA’s settings
read
Reads and displays information from
the VS0110HA.
Reset