System Messages
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
bbbbb
5014 (VMD_UNKCALL), INFORM
unknown <string> extension <string> from integrated switch
The Voice Mail Database DIP was given an extension for the call_answer or
voice_mail service that it could not find in the database. This message is printed
only when such extension was determined through integration with the switch.
The probable explanation for the message is that the called person (in the case
of call_answer) or the caller (in the case of voice_mail) is not properly registered
as a subscriber on the AUDIX Voice Power system.
Verify the presence of the extension.
If this problem persists, contact your field service representative.
5015 (VMD_ADMERR), MAJOR
admin process error: <string>
The Voice Mail Database DIP has received bad input data from an AUDIX Voice
Power Administration window.
If this problem persists, contact your field service representative.
5016 (VMD_VROPERR), MAJOR
VROP problem: <string>
There was a failure for a request made to VROP by the Voice Mail Database
DIP. VROP encountered a failure while attempting to service the request or it
may not have responded to the request.
If this problem persists, contact your field service representative.
5017 (VMD_MDWARN), MAJOR
couldn’t send MD warning: <string>
The Voice Mail Database DIP was unable to send a Voice Mail message to the
Message Drop Administrator. The purpose of the message was to warn the
administrator that the Message Drop mailbox contains a large number of mail
messages.
Make sure that a Message Drop Administrator has been designated. This
can be done through the Service Administrator Registration window.
Also, the Message Drop Administrator should listen to and delete most or
all of the Message Drop messages.
5018 (VMD_SHMFAIL), MAJOR
problem with shmem: <string>
The Voice Mail Database DIP was unable to attach a shared memory segment.
Contact your field service representative for assistance.
B-37