93
Dirt collector
Place a basin under the red dirt
collector to collect the dirty
and aggressive condensate water.
:HDUSURWHFWLYHFORWKLQJOLNHODWH[
gloves and safety glasses.
-
Dismantle the dirt collector by
unscrewing it. Check the red cup for
pollution.
- Clean it by rinsing it with water.
-
Re-grease the O-rings with acidfree
O-ring grease to facilitate easy
assembly.
-
If the red dirt collector shows any
leakage, it has to be replaced.
In case of leakage you can remove
the drainage cup to remove eventual
water/condense from the boiler.
Take the device back into operation
DQGFRQGXFWDÀXHJDVDQDO\VLV
(refer to chapter Check O
2
/CO
2
).
Maintenance
Maintenance details
)URPIDFWRU\D¿[HGQXPEHURIUXQQLQJ
months is set for service interval. The
number of running months cannot be
changed. After expiring of the number
of running months the message
1730 : Sched..Maintenance-Call
Service (when read-out is on boiler
status) is displayed on the screen.
During the messages 1730 : Sched..
Maintenance-Call Service the boiler
remains fully operational. If the
maintenance activities, as described
hereinbefore, have been carried out,
the counter has to be reset.
To reset the counter, the following
procedure has to be followed (starting
from a blue screen):
Go to installer menu
full menu
24.17 maintanance
24.17.2 reset maintanance counter.
The counter is reset to the same
number of months as set from
factory. The message 1730 : Sched..
Maintenance-Call Service is no longer
displayed.
Maintenance warning
A