Technical description

 

 

 

Technical data

 

ErP data

 

TRIGON L PLUS

 

  

  

  

 

75

 

105

 

Permit

 

  

  

  

 

CE0063CT3449

 

 

Category

 

  

  

  

 

GB: II2H3P

 

 

Heat exchanger type

 

  

  

  

 

iConXL1

 

iConXL2

 

Output

 

G20

 

Full load

 

80/60°C

 

kW

 

65,4

 

90,2

 

 

 

  

 

40/30°C

 

kW

 

72,0

 

99,0

 

 

 

  

Low load

 

80/60°C

 

kW

 

14,6

 

18,1

 

 

 

  

 

40/30°C

 

kW

 

16,1

 

19,9

 

 

 

G31

 

Full load

 

80/60°C

 

kW

 

65,4

 

90,2

 

 

 

  

 

40/30°C

 

kW

 

72,0

 

99,0

 

 

 

  

Low load

 

80/60°C

 

kW

 

23,2

 

34,3

 

 

 

  

 

40/30°C

 

kW

 

25,6

 

37,7

 

Input

 

G20

 

Full load

    

kW

 

66,7

 

92,3

 

 

 

  

Low load

    

kW

 

14,9

 

18,5

 

 

 

G31

 

Full load

    

kW

 

66,7

 

92,3

 

 

 

  

Low load

    

kW

 

23,6

 

35,0

 

Gas consumption

 

G20

 

Full load

    

m3/h

 

7,1

 

9,8

 

 

 

  

Low load

    

m3/h

 

1,6

 

2,0

 

 

 

G31

 

Full load

    

kg/h

 

5,5

 

7,6

 

 

 

  

Low load

    

kg/h

 

1,92

 

2,84

 

Boiler efficiency

 

  

Full load

 

80/60°C

 

%

 

98,0

 

97,7

 

 

 

  

Full load

 

40/30°C

 

%

 

108,0

 

107,3

 

 

 

  

Low load

 

80/60°C

 

%

 

98,3

 

97,9

 

 

 

  

Low load

 

40/30°C

 

%

 

108,4

 

107,6

 

Gas type

 

  

  

  

 

Natural gas or Gas propane

 

 

CO2   natural gas

 

  

min./max

    

Vol. %

 

8,7 / 9,3

 

CO2   propane gas

 

  

min./max

    

Vol. %

 

10,2 / 10,8

 

O2   natural gas

 

  

min./max

    

Vol. %

 

5,3 / 4,3

 

NOx class

 

  

 

  

 

6

 

6

 

Max. flue gas temperature

 

  

 

  

80/60°C

 

61

 

71

 

Mass flow of flue gas

 

  

 

  

kg/h

 

120

 

166

 

Overpressure at boiler output

 

  

max

 

  

Pa

 

156

 

243

 

Water content

 

  

max

 

  

l

 

9,3

 

13,9

 

Weight

 

  

 

  

kg

 

73

 

80

 

Gas flow pressure 

-

 standard

 

  

 

  

mbar

 

20

 

Gas flow

-

pressure min./max.

 

  

 

  

mbar

 

17 / 25

 

 

Water pressure

 

  

min./max

    

bar

 

0,7 / 6

 

Voltage/frequency

 

  

min./max

    

Volt/Hz

 

230 / 50

 

Max. power consumption

 

  

 

  

W

 

137

 

120

 

Power consumption part load

 

  

 

  

W

 

45

 

95

 

Power consumption stand by

 

  

 

  

W

 

5

 

5

 

Width / depth / height

 

  

 

  

mm

 

530/595/1050

 

530/675/1050

 

Gas external thread

 

  

 

  

R

 

Rp 1.1/4"

 

Rp 1.1/4"

 

Flow/return external thread

 

  

 

  

R

 

Rp 2"

 

Rp 2"

 

Flue gas connection PPS

 

  

Diameter

    

DN

 

100

 

100

 

Outdoor air connection

 

  

Internal

 

  

in mm

 

100

 

100

 

Condensate connection PVC

 

  

External

    

in mm

 

35,5

 

35,5

 

ErP data according to 813/2013/EU

 

 

75

 

105

 

Seasonal room

-

heating energy efficiency class

 

 

A

 

 

 

Nominal heat output

 

Pn (kW)

 

64

 

88

 

Seasonal room

-

heating energy efficiency class

 

η

s (%)

 

93

 

93

 

Annual energy consumption

 

QHE  (GJ)

 

199

 

272

 

Noise output level, inside

 

LWA  (dB)

 

65

 

60

 

 

At rated heat output and high

-

temp regime 80/60°C

 

P4 (kW)

 

65,3

 

90,2

 

At 30 % of rated heat output and low

-

temp regime 36/30°C

 

P1 (kW)

 

21,8

 

30,2

 

At rated heat output and high

-

temp regime (GCV)

 

η4 (%)

 

88,2

 

88,0

 

At 30 % of rated heat output and low

-

temp regime (GCV)

 

η1 (%)

 

98,3

 

98,2

 

 

 

At full load

 

elmax (kW)

 

0,137

 

0,120

 

At part load

 

elmin (kW)

 

0,045

 

0,095

 

In standby mode

 

Psb (kW)

 

0,005

 

0,005

 

Standby heat loss

 

Pstby (kw)

 

0,086

 

0,075

 

Содержание XL-W 105

Страница 1: ...Planner Manual XL W XL W Gas Condensing Wall Hung Boiler Single Installations 75 to 210 kW Cascade Installations up to 1600 kW 1V0 08 2020...

Страница 2: ...2...

Страница 3: ...ation 20 Dimensions cascade Wall mounted 21 Dimensions cascade Freestanding in line 23 Dimensions cascade Freestanding Back to Back 25 Clearances single boiler 27 Declaration of conformity 28 Norms an...

Страница 4: ...Standard schemes Standard schemes 56 Accessories Controls Single boiler Gas Single boiler Hydraulics Single boiler Others Cascade Frame Cascade Gas Cascade Hydraulics Cascade Specifically for Italy Ca...

Страница 5: ...a fully modulating condensing boiler with one or two pre mix burners The control unit of the boiler adapts the modulation ratio automatically to the heat de mand requested by the system This is done b...

Страница 6: ...60 70 100 120 140 26 Water pipe conection reduction 1 1 2 optional 27 Gas pipe conection re duction 1 optional T1 Flow sensor T1a Secondary flow sensor T2 Return sensor P1 Water pressure sensor APS A...

Страница 7: ...re regulation of the heating flow tem perature DHW temperature regulation e bus2 connections for connection with accessories from the ATAG offer Ready for connection to BMS systems supported protocols...

Страница 8: ...ulation of the heating flow tem perature DHW temperature regulation e bus2 connections for connection with accessories from the ATAG offer Ready for connection to BMS systems supported protocols Modbu...

Страница 9: ...temperature regulation of the heating flow tem perature DHW temperature regulation e bus2 connections for connection with accessories from the ATAG offer Ready for connection to BMS systems supported...

Страница 10: ...temperature regulation of the heating flow tem perature DHW temperature regulation e bus2 connections for connection with accessories from the ATAG offer Ready for connection to BMS systems supported...

Страница 11: ...temperature regulation of the heating flow tem perature DHW temperature regulation e bus2 connections for connection with accessories from the ATAG offer Ready for connection to BMS systems supported...

Страница 12: ...e temperature regulation of the heating flow tem perature DHW temperature regulation e bus2 connections for connection with accessories from the ATAG offer Ready for connection to BMS systems supporte...

Страница 13: ...ent max l 9 3 13 9 Weight kg 73 80 Gas flow pressure standard mbar 20 Gas flow pressure min max mbar 17 25 Water pressure min max bar 0 7 6 Voltage frequency min max Volt Hz 230 50 Max power consumpti...

Страница 14: ...a 143 200 215 265 Water content max l 16 8 16 8 21 3 25 8 Weight kg 127 127 132 140 Gas flow pressure standard mbar 20 Gas flow pressure min max mbar 17 25 Water pressure min max bar 0 7 6 Voltage fre...

Страница 15: ...nnection mm 35 35 E Air intake conn mm 185 185 a Boiler flow connection 2 2 F Flue air intake mm 150 150 Boiler flow connection 1 1 2 1 1 2 G Return connection mm 103 103 r Boiler return connection 2...

Страница 16: ...te connection mm 35 35 E Air intake conn mm 185 185 a Boiler flow connection 2 2 F Flue air intake mm 150 150 Boiler flow connection 1 1 2 1 1 2 G Return connection mm 103 103 r Boiler return connecti...

Страница 17: ...for da mage to occur Lifting and carrying precautions Wear protective clothing and gloves to protect from any sharp edges The boiler has to be lifted from the front with a forklift truck for transpor...

Страница 18: ...king instructions are printed on the carboard box Please follow the proposed steps Boiler Installation The installation location of the CH boiler s has to be and remain frost free It is NOT necessary...

Страница 19: ...sists with sharing the load and run times of individual ap pliance The capacity of the hydraulic pipes gas line and low loss header are adjusted to the selected overall demand When installing the a si...

Страница 20: ...s Cascade XL W cascade installation Legend 1 Air supply 2 Flue gas discharge Air supply 3 Cascade manager Accessories 4 Gas isolation valve 5 Service valves flow and return 6 Non return valve Legend A...

Страница 21: ...21 Dimensions Cascade XL W Cascade installation XL W Cascade examples wall mounted XL W 5 boilers wall mounted in line XL W 8 boilers wall mounted in line...

Страница 22: ...22 Dimensions Cascade XL W Cascade installation XL W Cascade examples free standing in line XL W 2 boilers XL W 3 boilers free standing in line...

Страница 23: ...23 Dimensions Cascade XL W Cascade installation XL W Cascade examples free standing in line XL W 5 boilers free standing in line XL W 8 boilers free standing in line...

Страница 24: ...24 Dimensions Cascade XL W Cascade installation XL W Cascade examples free standing back to back XL W 3 boilers free standing back to back XL W 4 boilers free standing back to back...

Страница 25: ...25 Dimensions Cascade XL W Cascade installation XL W Cascade examples free standing back to back XL W 6 boilers free standing back to back XL W 8 boilers free standing back to back...

Страница 26: ...rain 4 Gas 5 Flue gas outlet 6 Air supply Pay attention to the minimum distance required between the boilers walls and ceiling for installing and removing the hou sing If you have opted to build the h...

Страница 27: ...27 Technical description Declaration of conformity...

Страница 28: ...5502 2 Requirements for gas fired systems Part 2 1 Type C such as B2 B3 and B5 with nominal caloric debit 1000 kW EN 55014 1 2011 EMC Requirements for household appliances electrical tools and similar...

Страница 29: ...quipment may not be used by children by persons with a hindrance of bodily mental or sensory capacities or with in sufficient experience and knowhow unless they are su pervised or have received cor re...

Страница 30: ...piping system into consideration The central heating installation must be de aerated properly be fore it is put into operation Please review the Chapter Commissioning in this regard If a regular toppi...

Страница 31: ...opyleneglycol propane 1 2 diol inhibitors 50 w w Anti freeze Sentinel X500 Monopropyleneglycol inhibitors Kiwa certified 20 50 w w Anti freeze Fernox Alphi 11 Monopropyleneglycol inhibitors Kiwa certi...

Страница 32: ...king Water Directive 98 83 EC dated 3 November 1998 Distilled water Water in which no more salts are present Softened water Water from which calcium and magnesium ions have been parti ally removed Dem...

Страница 33: ...3 back towards the boiler Air supply connection If required a separate room sea led air supply tube may be connected via the inclusion of the optional air supply connector fit ting The diameter must...

Страница 34: ...The flue gas and suction air ducts via the roof terminal must be in the same square area C43 Suction air and flue gas duct via the chimney system which is integrated in the building C53 Section the ai...

Страница 35: ...flue gas outlet system The air supply may also be supplied collectively but if the boiler room is suitable for that purpose for that purpose it may also be obtained ffrom this area open device Boiler...

Страница 36: ...l terminal As a result roof terminals are pre ferred In a closed installation roof terminals should be at the same height preventing flue gas from being sucked in by the other boiler recirculation Out...

Страница 37: ...enience particularly in the case of wall terminal As a result roof terminals are preferred In a closed installation roof terminals should be at the same height preventing flue gas from being sucked in...

Страница 38: ...ated with thermal draft under atmospheric circumstances NOTE 1 IPX0D at flue category B23 and B33 Open system underpressure Output 80 60 d minimum diameter in mm kW h 2 5 h 5 9 h 9 13 h 13 17 114 240...

Страница 39: ...er pressure calculated with thermal draft under atmospheric ircumstances Closed system underpressure parallel Output 80 60 d minimum diameter in mm kW h 2 5 h 5 9 h 9 13 h 13 17 114 240 240 220 220 22...

Страница 40: ...lengths of the flue gas outlet air supply Open system with over pressure NOTE 1 IPX0D at flue category B23 and B33 2 Only with bus cable connected 3 Adjust parameter 102 to 2 Open system overpressure...

Страница 41: ...ameter and venting lengths of the flue gas outlet air supply Closed system with over pressure Closed system overpressure parallel Output 80 60 d minimum diameter in mm kW h 2 5 h 6 10 h 11 15 h 16 20...

Страница 42: ...ler and are led to the electronics pa nel at the front of the boiler The electric diagram must be ob served during all electrical connection works see the follo wing pages A 230V 50Hz mains electrical...

Страница 43: ...ons are only to be carried out by qualified person Electrical connections above can be reached following the steps below 1 Remove the front panel 2 Press both external sides of the control unit HMI E...

Страница 44: ...44 Boiler Installation Electrical connection...

Страница 45: ...45 Boiler Installation Electrical connection...

Страница 46: ...Values None 0 System Pump 1 HC1 Pump 2 Circulating Pump 3 DHW Intermediate Circuit 4 BUF Filling Pump 5 Storage Tank Transfer Pump 6 Heat Generation Shut off Valve 7 Heat Request 8 Alarm Output 9 Flue...

Страница 47: ...1 24 6 0 Commercial Boiler 26 32 6 0 Commercial Boiler Slave 1 7 8 12 6 4 MTS 2 Multi In Temp 2 24 6 1 Commercial Boiler 26 32 6 1 Commercial Boiler Slave 1 7 8 12 6 5 MTS 3 Multi In Temp 3 24 6 2 Co...

Страница 48: ...6 4 Commercial Boiler 26 32 6 4 Commercial Boiler Slave 1 7 8 12 6 7 PADIN 2 Multi In AD 2 24 6 5 Commercial Boiler 26 32 6 5 Commercial Boiler Slave 1 7 8 12 6 8 PADIN 3 Multi In AD 3 24 6 6 Commerci...

Страница 49: ...flue gas sensor With a setting for max Temperature and system has to switch off or a set temperature where system has to reduce the power Weather Dependent Regulation When WDR is used an outdoor sens...

Страница 50: ...For giving feedback to the BMS this output gives a 0 10 Volt signal as indication of load Pump Modulation This output can be set as a controller for several pump types For types see scheme on pages DH...

Страница 51: ...ith this system HCs DHW Changeover External controller selects if the sys tem can only be active for DHW or for CH and DHW Heat Generation Lock As long as the input is open all heat request are blocke...

Страница 52: ...52 Boiler Installation Electrical connection Cascade control...

Страница 53: ...as valve B3 Flow temp sensor F1 Fuse 6 3A 250V A Master PCB A8 Circulation pump B4 2nd flow temp sensor F2 Fuse 6 3A 250V A1 Ionisation electrode A9 Water pressure sensor B5 Return temp sensor F3 Fuse...

Страница 54: ...ZONES Clip permits to connect two clips via eBUS in order to control up to 6 zones direct mixing or a combination of them This means connect one clip in on a single boiler and up to 2 clip in into a...

Страница 55: ...ot DV Drain valve EV Expansion vessel GSV Gas shut off valve HC Heating Circuit IV Isolation valve LLH Low loss header MF Dirt separator magnetic filter NRV Non return valve OF Overflow pipe PU Pressu...

Страница 56: ...Common flow temperature sensor 10K C Clip In 3 zone RT1 Room thermostat On Off RT2 Room thermostat On Off A Mixing Valve HC2 B Heating circuit pump HC1 C Heating circuit pump HC2 D Flow sensor HC2 E...

Страница 57: ...ERV Expansion relief valve EV Expansion vessel GSV Gas shut off valve HC Heating Circuit ID Inspection door IV Isolation valve LLH Low loss header MF Dirt separator magnetic filter NRV Non return valv...

Страница 58: ...Common flow temperature sensor 10K C DHW re circulating temperature sensor 10K T3 DHW temperature sensor 10K D Clip In 3 zone RT1 Room thermostat On Off RT2 Room thermostat On Off T7 Outdoor sensor o...

Страница 59: ...valve ERV Expansion relief valve EV Expansion vessel GSV Gas shut off valve HC Heating Circuit ID Inspection door IV Isolation valve LLH Low loss header MDV Motorised diverter valve MF Dirt separator...

Страница 60: ...switch 2 must be set in ON position G Main power connection to boiler board A Main power supply 230V 50Hz B Clip In power 230V 50Hz MDV Motorised diverter Valve 230 120 VAC 1A max CP DHW re circulati...

Страница 61: ...sion relief valve EV Expansion vessel GSV Gas shut off valve HC Heating Circuit ID Inspection door IV Isolation valve LLH Low loss header MF Dirt separator magnetic filter NRV Non return valve OF Over...

Страница 62: ...iler Ebus Input I DIP switch 2 must be set in ON position J Main power connection to boiler board A Main power supply 230V 50Hz B Clip In power 230V 50Hz Ch P DHW Charging pump 230 120 VAC 1A max CP D...

Страница 63: ...cable AAV Automatic air vent ADS Air dirt separator BV Balancing valve C Pi Condensing pipe CWS Cold water supply DP Dosing pot DV Drain valve EV Expansion vessel GSV Gas shut off valve HC Heating Cir...

Страница 64: ...ions A Main power supply 230V 50Hz B Heating circuit pump HC1 230V 50Hz T10 Common flow temperature sensor 10K C Cascade connection to slave board External controller 0 10 Volt A Main power supply 230...

Страница 65: ...LUS 3905122 BMS BUS MODULE KNX TH R L PLUS 3905123 The BMS BUS Module allows communication between a BMS system and the boiler using LON BACNET MODBUS KNX protocol For each protocol there is a dedicat...

Страница 66: ...ilter size GF507 1 3905104 GAS FILTER 170 200KW SINGLE BOILER TH R L PLUS Filter size 1 GF510 1 3905105 It is recommended to use a gas filter in the gas connection to the boiler to prevent im purities...

Страница 67: ...TLPLUS Kit contains shut off valves for water flow return and gas connections and a 6 bar safety valve Connections system side Water G 2 Flat gasket surface Gas Rp 1 3905150 CONNECTION KIT BOILER DHW...

Страница 68: ...68 Accessories Hydraulics Single boiler Dimensional sketch for 3905173 LLH dT10 20K WALL HUNG TLPLUS...

Страница 69: ...CB110 56M CB110 56M SAP code 3905186 3905186 3905186 3905187 3905187 3905187 3905187 m3 h 4 89 5 62 7 76 9 53 11 23 13 36 15 51 kPa 8 2 11 2 20 7 7 3 10 3 14 5 19 3 DESCRIPTION SAP CODE PLATE HEAT EX...

Страница 70: ...70 Accessories Hydraulics Single boiler dT10K CB110 26M CB110 56M dT15K CB112 26L CB112 52L dT20K CB112 38M CB112 68M...

Страница 71: ...0kg granulate GIALIT K L x B x H 420 x 300 x 240 mm Max heat input 450kW Inlet G1 Max condensate flow 54l h Outlet G1 12055172 NEUTRALIZATION BOX DN3 INCL GRANULATE Including 2x25kg granulate GIALIT K...

Страница 72: ...05134 INSULATION COLLECTOR DN65 DN100 1BOILER TLPLUS Insulation set for a flow return collector tube 3905136 CASCADE DEAERATOR TLPLUS 3905137 CASCADE FRAME FOOT L SHAPE WH B2B TLPLUS 3905142 CASCADE F...

Страница 73: ...the boiler 3905110 TAE TAS GAS V KIT LINE WH DHW TH LPLUS Boiler line cascade connection kit with DHW 3 way valve and TAE TAS gas valve When the temperature of the TAE TAS valve body reaches 100 C fo...

Страница 74: ...pe The switch is fitted on a DN65 flange and comes with bolts and gasket to be fitted on the end of the cascade gas collector 3905102 GAS PIPE DN65 DUO Gas pipe DN65 to be used for cascade using the D...

Страница 75: ...loss header suitable up to 1 000kW The low loss headers comes standard with adjustable feet automatic air vent drain valve pocket for temperature sensor T10 M16x55 bolts spring washers and nuts 390503...

Страница 76: ...76 Accessories Cascade Low loss headers Dimensional sketch for 3905033 LLH DN65 Dimensional sketch for 3905034 LLH DN100...

Страница 77: ...77 Accessories Cascade Low loss headers Dimensional sketch for 3905176 LLH DN100 DUO...

Страница 78: ...able up to 465kW 3905196 CASCADE PHE CONNECTION KIT DN65 3905197 CASCADE PHE CONNECTION DN100 Connection kit to connect the plate heat exchanger to the cascade kit Includes a deaerator 8L expansion ve...

Страница 79: ...N100 flanges gaskets bolts wash ers and nuts 3905027 CASCADE BEND 90 DN65 TLPLUS Set of 2 pieces 90 bends in DN65 to change the direction of the pipe work 3905035 CASCADE BEND 90 DN100 TLPLUS Set of 2...

Страница 80: ...e collector end piece with syphon 3905199 FLUE SIPHON SET DN200 TLPLUS 200mm Flue collector end piece with syphon 3905201 CASCADE FLUE KIT DN150 B2B TLPLUS Flue collector 150mm with 100mm boiler conne...

Страница 81: ...81 ATAG Heating Technology UK Ltd Suite 32 80 Churchill Square Business Centre Kingshill West Malling Kent ME19 4YU www atagheating co uk Service...

Отзывы: