4 x 1,5 mm²
H05V2V2-F
2 phases - 1 neutral
2 x 10 A
4 x 1,5 mm²
H05V2V2-F
2 phases - 1 neutral
2 x 06 A
5 x 1,5 mm²
H05V2V2-F
2 phases - 2 neutral (only for NL)
2 x 16 A
4 x 1,5 mm²
H05V2V2-F
3 phases (only for BE)
3 x 16 A
4 x 4,0 mm²
H05V2V2-F
2 phases - 1 neutral
2 x 32 A
3 x 6,0 mm²
H05V2V2-F
1 phase - 1 neutral
1 x 48 A
3 x 6,0 mm²
H05V2V2-F
1 phase - 1 neutral
1 x 35 A
3 x 4,0 mm²
H05V2V2-F
1 phase - 1 neutral
1 x 32 A
3 x 4,0 mm²
H05V2V2-F
1 phase - 1 neutral
1 x 25 A
3 x 2,5 mm²
H05V2V2-F
1 phase - 1 neutral
1 x 20 A
3 x 1,5 mm²
H05V2V2-F
1 phase - 1 neutral
1 x 16 A
Connecting an ‘open window’ sensor
The use of sensor type ‘FDS 100’ is recommended if a window sensor must be installed. The sensor
must be of the potential-free NO (normally open) contact type. It must be connected to the designated
port on the motor control unit (MCU) in the enclosure at the front of the appliance. A cord of type
H05VV-F 2x0,5 mm
2
(or similar) is recommended for connecting a window sensor. Without a window
sensor, a jumper closes the electrical circuit.
'open window' sensor
connection
1. Unscrew and remove the cover of the MCU enclosure.
2. Remove the jumper of the sensor connection.
3. Connect the wires of the cord to the sensor connection.