Clean grease filter indicator
The extraction module has a filter indicator. This indicator flashes when the grease filters need to be
cleaned. Three use intensities can be set, which determine the cleaning interval of the grease filters.
By selecting the correct intensity of use based on cooking habits, the filters will not need to be
cleaned more than necessary.
See the table for the required grease filter cleaning interval.
Filter cleaning after
(hour):
Intensity of use
Indication
40
Cooking and frying with little use of greases and
oils.
L1
20
Cooking and frying with moderate use of greases
and oils.
L2 (default)
10
Cooking and frying with lots of use of greases
and oils.
L3
40
Manual: The filters can be cleaned at any time
(before signalled by the filter indication). The filter
indication can then be reset. Note! Always reset
the filter indicator after cleaning the filters. In the
‘off’ setting, the filter indicator appears only if you
have not cleaned the filters for a long time.
off
Replace recirculation filter indicator
The extraction module has a filter indicator. This indicator and the letter ‘r’ on the display flash when
the recirculation filter needs to be replaced.
The recirculation filter has a replacement interval of 300 operating hours. See ‘Replacing the
recirculation filter’ in chapter '
'.
26
Use