Installation & Servicing Instructions ATAG E-Series
8
5.1
Dimensions
type of unit
E22S
E22C
E32S
E32C
A height
mm
650
650
650
650
B height with expansion vessel
mm
-
-
870
870
C width
mm
500
500
500
500
D depth
mm
395
395
395
395
E left side / flue gas exhaust
mm
335
335
335
335
F centre to centre / flue - airintake
mm
120
120
120
120
G back / flue gas exhaust
mm
270
270
270
270
H left side / gas pipe
mm
250
250
250
250
J left side / flow pipe
mm
150
150
150
150
K left side / return pipe
mm
350
350
350
350
L left side / condensation pipe
mm
405
405
405
405
N left side / cold water pipe
mm
285
285
P left side / hot water pipe
mm
215
215
Q pipe lenght of g*
mm
19
19
215
215
R pipe lenght of c*
mm
40
40
40
40
S pipe lenght of c and f;r;k and w*
mm
50
50
160
160
T back / centre of pipe c;k and w*
mm
26
26
26
26
U back / centre of pipe f;g and r*
mm
50
50
50
50
dimensions
table 1
dimensions
(in mm)
figure 1
wall
ceiling
minimal 250mm
minimal
10 mm
D
F
R
S
C
P
T
Q
H
J
K
L
G
U
N
E
B A
type of unit
E22S
E22C
E32S
E32C
air supply / flue gas system
mm 60 / 100 60 / 100 60 / 100 60 / 100
gas pipe - g
½"
female
½"
female
½"
female
½"
female
central heating flow pipe - f
22 mm
22 mm
¾" ext.
¾" ext.
central heating return pipe - r
22 mm
22 mm
¾" ext.
¾" ext.
condensation discharge pipe - c
22 mm
22 mm
22 mm
22 mm
cold water pipe - k
15 mm
½"ext.
hot water pipe - w
15 mm
½"ext.
connection diameters
table 2
boiler connections/mounting points
figure 3
54
332
619,5
337
supporting point
52
220
f w g k r c
Содержание E 22C