»SAPHIR 550/560
Operating Manual
GmbH
- 29 -
Stand: 03.02.2020
4.2
Malfunction messages on the display
Error No.:
Malfunction
Cause
Measure
E50000
Head cannot be taken upwards
during reference path run.
Blockage
Remove blockage
Frequency rectifier breakdown
E50001
Error frequency rectifier for wheel
right
Different causes possible
Acknowledge message
If repeated, then
E50002 Error frequency rectifier for head
Different causes possible
Acknowledge message
If repeated, then
E50003 Cover cannot be brought upwards
Blockage
Remove blockage
No/not enough comp. air
Check compressed air
E50004 Error frequency rectifier for wheel left Different causes possible
Acknowledge message
If repeated, then
Содержание SAPHIR 550