5-4
Startup/Shutdown
3.
Select
Calculate Master Offsets
from the cascading menu.
>
If
Calculate Master Offsets
is not available, select
Machine Offsets Parameters
and
activate
Calculate Master Offsets
in the Machine Offsets Parameters dialog box.
4.
Under
Machine Offsets Mode
, select
Calculate Master Offsets
.
?
NOTE
If you are changing from
Valve Offsets
to
Calculate Master Offsets
, it is recommended
that you exit FmNT and restart before performing the
Calculate Master Offsets
routine.
5.
Enter Machine Setup Parameters; click
OK
.
6.
Follow the on-screen prompts to complete the setup.
>
Consult the
Fluidmove for Windows NT User Guide
or FmNT Online Help for assistance.
?
NOTE
Calculate Master Offsets
and
Find Needle XYZ
must be used together.
Valve Offsets
Valve Offsets
takes you through a series of on-screen prompted functions for defining the XYZ locations
of the Purge and Weigh Stations, calculating the needle-to-height sensor Z offset, the needle-to-camera
XY offset, and the camera-to-height sensor XY offset. This routine is typically performed after initial
start-up if significant changes to the system are made or if the dispensing system or software is upgraded
or reinitialized. See the
Fluidmove for Windows NT User Guide
or Online Help for more guidance.
To perform Valve Offsets:
1.
In the FmNT Main Window, click on
Configuration
.
2.
Choose
Machine Offsets
.
3.
Select
Valve Offsets
from the cascading menu.
>
If
Valve Offsets
is not available, select
Machine Offsets Parameters
and activate
Valve
Offsets
in the Machine Offsets Parameters dialog box. Click on
OK
.
4.
Return to
Configuration
.
5.
Choose
Machine Offsets
.
6.
Select
Valve Offsets
from the cascading menu.
7.
Click on
Run
to begin the first machine offsets procedure. Follow the on-screen prompts to
complete the setup routine for your specific application.
8.
If your system is configured for dual-action fluid dispensing, repeat the above procedures for
Valve 2.
?
NOTE
If you are changing from
Calculate Master Offsets
to
Valve Offsets
, it is recommended
that you exit FmNT and restart before performing the
Valve Offsets
routine. See the
Fluidmove for Windows NT User Guide
or Online Help for more guidance.
Содержание Century C-721 Series
Страница 2: ...Revision History Revision Date Description Pages Affected A 5 01 Initial Release All ...
Страница 8: ......
Страница 12: ......
Страница 36: ......
Страница 76: ......
Страница 81: ...Maintenance 7 5 Item Description 1 Purge Boot 2 Purge Station Lid Figure 7 2 Replacing the Purge Boot 1 2 ...
Страница 108: ......
Страница 112: ...11 4 Needle Sensor Item Description 1 Tactile sensor hat 2 Tactile sensor Figure 11 2 Tactile Sensor Exposed 1 2 ...
Страница 114: ......
Страница 117: ...Needle Heater 12 3 Figure 12 2 HT 06 Figure 12 3 HT 10N ...
Страница 119: ...Needle Heater 12 5 Item Description 1 Luer Lock Fitting Figure 12 4 HT 06 on a DV 6000 Pump with Luer Lock Fitting 1 ...
Страница 122: ......
Страница 138: ......