Needle Sensor
11-5
Needle Sensor Troubleshooting
Table 11-1 Needle Sensor Troubleshooting
Symptom
Possible Cause
Recovery
During Setup routine, error
indicates that the tactile
sensor is already engaged.
Tactile sensor “hat” is stuck
in the down position.
See Tactile Sensor Error below.
LED does not come ON
during routine.
Needle Sensor malfunction.
Call an Asymtek service technician.
LED is constantly ON.
Dust in the sensor.
Clean sensor slots with a soft cloth or
by blowing air through them.
Needle jams too far into the
needle sensor slot.
Height change beyond
capability.
Reru
n
Needle Sensor setup
.
Needle-to-Height Sensor
offset is inaccurate.
Fluid build-up on probe tip
caused inaccurate Height
Sensor calibration.
Clean the probe tip with a soft cloth
and recalibrate the Height Sensor.
Specifications for Needle Sensor
Size
159 x 100 x 21 mm
(6.25 x 4 x 0.813 in)
Minimum needle length
1.4 mm (0.125 in)
Minimum needle diameter
30 gauge
Accuracy
±
0.1 mm (
±
0.005 in)
Repeatability
±
0.051 mm (
±
0.002 in)
Содержание Century C-721 Series
Страница 2: ...Revision History Revision Date Description Pages Affected A 5 01 Initial Release All ...
Страница 8: ......
Страница 12: ......
Страница 36: ......
Страница 76: ......
Страница 81: ...Maintenance 7 5 Item Description 1 Purge Boot 2 Purge Station Lid Figure 7 2 Replacing the Purge Boot 1 2 ...
Страница 108: ......
Страница 112: ...11 4 Needle Sensor Item Description 1 Tactile sensor hat 2 Tactile sensor Figure 11 2 Tactile Sensor Exposed 1 2 ...
Страница 114: ......
Страница 117: ...Needle Heater 12 3 Figure 12 2 HT 06 Figure 12 3 HT 10N ...
Страница 119: ...Needle Heater 12 5 Item Description 1 Luer Lock Fitting Figure 12 4 HT 06 on a DV 6000 Pump with Luer Lock Fitting 1 ...
Страница 122: ......
Страница 138: ......