System Specifications
8-1
8 System Specifications
Century C-721 Advanced IC and DCA Encapsulation System:
Fluid Control
Fluid Volume Accuracy
Volume accuracy is dependent on the fluid delivery system in use
and will be characterized and guaranteed by Asymtek for the
customer application and the specific encapsulation material
Dispensed Mass
Programmable within the dispensing pattern
Fluid/Valve Setup
Automatic dispense valve priming station
Needle Sensor
Automatic realignment of dispensing needle after replacement
Conveyor
Speed
Programmable, 254 mm/sec (10 in/sec) max
Carrier Types
Auer boats, lead frames or custom carriers
Rails
Fixed front with moveable rear standard
Width Adjustment
Motorized
Flow Direction
Configurable for left-to-right (standard) or right-to-left (optional) flow
Operation Modes
Automatic (SMEMA), manual and pass-through
Maximum Carrier Size
406 x 394 mm (16 x 15.5 in)
Minimum Carrier Size
25.4 x 50.8 mm (1.0 x 2.0 in) standard. Contact us about smaller
sizes
Part Management
Fiducial Location
Proprietary die corner detection and skipping algorithms, Picture-in-
monitor display
Software
Fluidmove for Windows NT controls all machine events and
provides Statistical Process Control (SPC) data logging
Z-Height Sensor
Low force (5 gram) tactile retractable sensor probe for
programmable dispensing heights
Thermal Management
Heat Stations
Up to three independently configured substrate heating stations
(pre-heat, dispense-heat and post-heat) with closed-loop
programmable setpoint control
Heat Source
Configurable with contact or impingement stations
Temperature Control
Closed-loop proportional-integral-derivative (PID) controllers
Heat Management
Forced-air cooling of the fluid maintains temperature within 5
°
C of
ambient
Motion System
X-Y Velocity
0 to 381 mm/s (0 to 15 in/s)
X-Y Positioning Accuracy
±
0.13 mm (
±
0.005 in)
X-Y-Z Repeatability
±
0.025 mm (
±
0.001 in)
X-Y Travel
508 x 432 mm (20 x 17 in)
Z Travel
89 mm (3.5 in)
Z Height Sensor
±
0.025 mm (
±
0.001 in) 5-gram force
Содержание Century C-721 Series
Страница 2: ...Revision History Revision Date Description Pages Affected A 5 01 Initial Release All ...
Страница 8: ......
Страница 12: ......
Страница 36: ......
Страница 76: ......
Страница 81: ...Maintenance 7 5 Item Description 1 Purge Boot 2 Purge Station Lid Figure 7 2 Replacing the Purge Boot 1 2 ...
Страница 108: ......
Страница 112: ...11 4 Needle Sensor Item Description 1 Tactile sensor hat 2 Tactile sensor Figure 11 2 Tactile Sensor Exposed 1 2 ...
Страница 114: ......
Страница 117: ...Needle Heater 12 3 Figure 12 2 HT 06 Figure 12 3 HT 10N ...
Страница 119: ...Needle Heater 12 5 Item Description 1 Luer Lock Fitting Figure 12 4 HT 06 on a DV 6000 Pump with Luer Lock Fitting 1 ...
Страница 122: ......
Страница 138: ......